欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT45DB321D-SU-SL955 参数 Datasheet PDF下载

AT45DB321D-SU-SL955图片预览
型号: AT45DB321D-SU-SL955
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位2.7伏的DataFlash [32-megabit 2.7-volt DataFlash]
分类和应用:
文件页数/大小: 57 页 / 1838 K
品牌: ATMEL [ ATMEL ]
 浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第20页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第21页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第22页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第23页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第25页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第26页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第27页浏览型号AT45DB321D-SU-SL955的Datasheet PDF文件第28页  
12. Deep Power-down  
After initial power-up, the device will default in standby mode. The Deep Power-down command  
allows the device to enter into the lowest power consumption mode. To enter the Deep Power-  
down mode, the CS pin must first be asserted. Once the CS pin has been asserted, an opcode  
of B9H command must be clocked in via input pin (SI). After the last bit of the command has  
been clocked in, the CS pin must be de-asserted to initiate the Deep Power-down operation.  
After the CS pin is de-asserted, the device will enter the Deep Power-down mode within the  
maximum tEDPD time. Once the device has entered the Deep Power-down mode, all instructions  
are ignored except for the Resume from Deep Power-down command.  
Command  
Opcode  
Deep Power-down  
B9H  
Figure 12-1. Deep Power-down  
CS  
SI  
Opcode  
Each transition  
represents 8 bits  
12.1 Resume from Deep Power-down  
The Resume from Deep Power-down command takes the device out of the Deep Power-down  
mode and returns it to the normal standby mode. To Resume from Deep Power-down mode, the  
CS pin must first be asserted and an opcode of ABH command must be clocked in via input pin  
(SI). After the last bit of the command has been clocked in, the CS pin must be de-asserted to  
terminate the Deep Power-down mode. After the CS pin is de-asserted, the device will return to  
the normal standby mode within the maximum tRDPD time. The CS pin must remain high during  
the tRDPD time before the device can receive any commands. After resuming form Deep Power-  
down, the device will return to the normal standby mode.  
Command  
Opcode  
Resume from Deep Power-down  
ABH  
Figure 12-2. Resume from Deep Power-Down  
CS  
Opcode  
SI  
Each transition  
represents 8 bits  
24  
AT45DB321D  
3597N–DFLASH–04/09