M65608E
DC Parameters
DC Test Conditions
Table 3. DC Test Conditions
TA = -55°C to + 125°C; Vss = 0V; VCC = 4.5V to 5.5V
Symbol
Description
Minimum
Typical
Maximum
Unit
Input leakage
current
IIX (1)
-1
–
1
µA
Output leakage
current
IOZ(1)
-1
–
–
–
–
1
0.4
–
µA
V
VOL (2)
VOH (3)
Output low voltage
Output high
voltage
2.4
V
1.
GND < Vin < VCC, GND < Vout < VCC Output Disabled.
2.
3.
V
V
CC min. IOL = 8 mA
CC min. IOH = -4 mA.
Consumption
Symbol
Description
65608E-30
65608E-45
Unit
Value
Standby supply
current
ICCSB (1)
ICCSB1 (2)
ICCOP (3)
2
2
mA
max
Standby supply
current
300
110
300
100
µA
max
max
Dynamic operating
current
mA
1.
2.
3.
CS1 > VIH or CS2 < VIL and CS1 < VIL.
CS1 > VCC - 0.3V or, CS2 < GND + 0.3V and CS1 < 0.2V.
F = 1/TAVAV, Iout = 0 mA, W = OE = VIH, Vin = GND or VCC, VCC max.
5
4151N–AERO–04/09