 浏览型号90USB1287-16AU的Datasheet PDF文件第128页浏览型号90USB1287-16AU的Datasheet PDF文件第129页浏览型号90USB1287-16AU的Datasheet PDF文件第130页浏览型号90USB1287-16AU的Datasheet PDF文件第131页浏览型号90USB1287-16AU的Datasheet PDF文件第133页浏览型号90USB1287-16AU的Datasheet PDF文件第134页浏览型号90USB1287-16AU的Datasheet PDF文件第135页浏览型号90USB1287-16AU的Datasheet PDF文件第136页  
The PWM resolution for fast PWM can be fixed to 8-, 9-, or 10-bit, or defined by either ICRn or  
OCRnA. The minimum resolution allowed is 2-bit (ICRn or OCRnA set to 0x0003), and the max-  
imum resolution is 16-bit (ICRn or OCRnA set to MAX). The PWM resolution in bits can be  
calculated by using the following equation:  
log(TOP + 1)  
R
= ----------------------------------  
FPWM  
log(2)  
In fast PWM mode the counter is incremented until the counter value matches either one of the  
fixed values 0x00FF, 0x01FF, or 0x03FF (WGMn3:0 = 5, 6, or 7), the value in ICRn (WGMn3:0 =  
14), or the value in OCRnA (WGMn3:0 = 15). The counter is then cleared at the following timer  
clock cycle. The timing diagram for the fast PWM mode is shown in Figure 14-7. The figure  
shows fast PWM mode when OCRnA or ICRn is used to define TOP. The TCNTn value is in the  
timing diagram shown as a histogram for illustrating the single-slope operation. The diagram  
includes non-inverted and inverted PWM outputs. The small horizontal line marks on the TCNTn  
slopes represent compare matches between OCRnx and TCNTn. The OCnx Interrupt Flag will  
be set when a compare match occurs.  
Figure 14-7. Fast PWM Mode, Timing Diagram  
OCRnx / TOP Update  
and TOVn Interrupt Flag  
Set and OCnA Interrupt  
Flag Set or ICFn  
Interrupt Flag Set  
(Interrupt on TOP)  
TCNTn  
(COMnx1:0 = 2)  
OCnx  
(COMnx1:0 = 3)  
OCnx  
1
2
3
4
5
6
7
8
Period  
The Timer/Counter Overflow Flag (TOVn) is set each time the counter reaches TOP. In addition  
the OCnA or ICFn Flag is set at the same timer clock cycle as TOVn is set when either OCRnA  
or ICRn is used for defining the TOP value. If one of the interrupts are enabled, the interrupt han-  
dler routine can be used for updating the TOP and compare values.  
When changing the TOP value the program must ensure that the new TOP value is higher or  
equal to the value of all of the Compare Registers. If the TOP value is lower than any of the  
Compare Registers, a compare match will never occur between the TCNTn and the OCRnx.  
Note that when using fixed TOP values the unused bits are masked to zero when any of the  
OCRnx Registers are written.  
The procedure for updating ICRn differs from updating OCRnA when used for defining the TOP  
value. The ICRn Register is not double buffered. This means that if ICRn is changed to a low  
value when the counter is running with none or a low prescaler value, there is a risk that the new  
ICRn value written is lower than the current value of TCNTn. The result will then be that the  
counter will miss the compare match at the TOP value. The counter will then have to count to the  
MAX value (0xFFFF) and wrap around starting at 0x0000 before the compare match can occur.  
The OCRnA Register however, is double buffered. This feature allows the OCRnA I/O location  