 浏览型号90USB1287-16AU的Datasheet PDF文件第121页浏览型号90USB1287-16AU的Datasheet PDF文件第122页浏览型号90USB1287-16AU的Datasheet PDF文件第123页浏览型号90USB1287-16AU的Datasheet PDF文件第124页浏览型号90USB1287-16AU的Datasheet PDF文件第126页浏览型号90USB1287-16AU的Datasheet PDF文件第127页浏览型号90USB1287-16AU的Datasheet PDF文件第128页浏览型号90USB1287-16AU的Datasheet PDF文件第129页  
AT90USB64/128  
14.5 Input Capture Unit  
The Timer/Counter incorporates an input capture unit that can capture external events and give  
them a time-stamp indicating time of occurrence. The external signal indicating an event, or mul-  
tiple events, can be applied via the ICPn pin or alternatively, for the Timer/Counter1 only, via the  
Analog Comparator unit. The time-stamps can then be used to calculate frequency, duty-cycle,  
and other features of the signal applied. Alternatively the time-stamps can be used for creating a  
log of the events.  
The Input Capture unit is illustrated by the block diagram shown in Figure 14-3. The elements of  
the block diagram that are not directly a part of the input capture unit are gray shaded. The small  
“n” in register and bit names indicates the Timer/Counter number.  
Figure 14-3. Input Capture Unit Block Diagram  
DATA BUS (8-bit)  
TEMP (8-bit)  
ICRnH (8-bit)  
ICRnL (8-bit)  
TCNTnH (8-bit)  
TCNTnL (8-bit)  
ICRn (16-bit Register)  
TCNTn (16-bit Counter)  
WRITE  
ACO*  
ACIC*  
ICNC  
ICES  
Analog  
Comparator  
Noise  
Canceler  
Edge  
Detector  
ICFn (Int.Req.)  
ICPn  
Note:  
The Analog Comparator Output (ACO) can only trigger the Timer/Counter1 ICP – not  
Timer/Counter3, 4 or 5.  
When a change of the logic level (an event) occurs on the Input Capture Pin (ICPn), alternatively  
on the analog Comparator output (ACO), and this change confirms to the setting of the edge  
detector, a capture will be triggered. When a capture is triggered, the 16-bit value of the counter  
(TCNTn) is written to the Input Capture Register (ICRn). The Input Capture Flag (ICFn) is set at  
the same system clock as the TCNTn value is copied into ICRn Register. If enabled (TICIEn =  
1), the input capture flag generates an input capture interrupt. The ICFn flag is automatically  
cleared when the interrupt is executed. Alternatively the ICFn flag can be cleared by software by  
writing a logical one to its I/O bit location.  
Reading the 16-bit value in the Input Capture Register (ICRn) is done by first reading the low  
byte (ICRnL) and then the high byte (ICRnH). When the low byte is read the high byte is copied  
into the high byte Temporary Register (TEMP). When the CPU reads the ICRnH I/O location it  
will access the TEMP Register.  