欢迎访问ic37.com |
会员登录 免费注册
发布采购

90USB1287-16AU 参数 Datasheet PDF下载

90USB1287-16AU图片预览
型号: 90USB1287-16AU
PDF下载: 下载PDF文件 查看货源
内容描述: 单片机具有ISP功能的Flash和USB控制器64 / 128K字节 [Microcontroller with 64/128K Bytes of ISP Flash and USB Controller]
分类和应用: 微控制器
文件页数/大小: 434 页 / 3172 K
品牌: ATMEL [ ATMEL ]
 浏览型号90USB1287-16AU的Datasheet PDF文件第123页浏览型号90USB1287-16AU的Datasheet PDF文件第124页浏览型号90USB1287-16AU的Datasheet PDF文件第125页浏览型号90USB1287-16AU的Datasheet PDF文件第126页浏览型号90USB1287-16AU的Datasheet PDF文件第128页浏览型号90USB1287-16AU的Datasheet PDF文件第129页浏览型号90USB1287-16AU的Datasheet PDF文件第130页浏览型号90USB1287-16AU的Datasheet PDF文件第131页  
AT90USB64/128  
Register has been read. After a change of the edge, the Input Capture Flag (ICFn) must be  
cleared by software (writing a logical one to the I/O bit location). For measuring frequency only,  
the clearing of the ICFn Flag is not required (if an interrupt handler is used).  
14.6 Output Compare Units  
The 16-bit comparator continuously compares TCNTn with the Output Compare Register  
(OCRnx). If TCNT equals OCRnx the comparator signals a match. A match will set the Output  
Compare Flag (OCFnx) at the next timer clock cycle. If enabled (OCIEnx = 1), the Output Com-  
pare Flag generates an Output Compare interrupt. The OCFnx Flag is automatically cleared  
when the interrupt is executed. Alternatively the OCFnx Flag can be cleared by software by writ-  
ing a logical one to its I/O bit location. The Waveform Generator uses the match signal to  
generate an output according to operating mode set by the Waveform Generation mode  
(WGMn3:0) bits and Compare Output mode (COMnx1:0) bits. The TOP and BOTTOM signals  
are used by the Waveform Generator for handling the special cases of the extreme values in  
some modes of operation (See “Modes of Operation” on page 130.)  
A special feature of Output Compare unit A allows it to define the Timer/Counter TOP value (i.e.,  
counter resolution). In addition to the counter resolution, the TOP value defines the period time  
for waveforms generated by the Waveform Generator.  
Figure 14-4 shows a block diagram of the Output Compare unit. The small “n” in the register and  
bit names indicates the device number (n = n for Timer/Counter n), and the “x” indicates Output  
Compare unit (A/B/C). The elements of the block diagram that are not directly a part of the Out-  
put Compare unit are gray shaded.  
Figure 14-4. Output Compare Unit, Block Diagram  
DATA BUS (8-bit)  
TEMP (8-bit)  
OCRnxH Buf. (8-bit)  
OCRnxL Buf. (8-bit)  
TCNTnH (8-bit)  
TCNTnL (8-bit)  
OCRnx Buffer (16-bit Register)  
TCNTn (16-bit Counter)  
OCRnxH (8-bit)  
OCRnxL (8-bit)  
OCRnx (16-bit Register)  
= (16-bit Comparator )  
OCFnx (Int.Req.)  
TOP  
OCnx  
Waveform Generator  
BOTTOM  
WGMn3:0  
COMnx1:0  
The OCRnx Register is double buffered when using any of the twelve Pulse Width Modulation  
(PWM) modes. For the Normal and Clear Timer on Compare (CTC) modes of operation, the  
double buffering is disabled. The double buffering synchronizes the update of the OCRnx Com-  
pare Register to either TOP or BOTTOM of the counting sequence. The synchronization  
127  
7593A–AVR–02/06  
 复制成功!