7.2
Static Characteristics
The electrical specifications in this document are preliminary. (See numbered notes)
Table 7-1.
Static Characteristics – GND = 0 VDC, TC = -55 to +125°C
Characteristic
Symbol
VIH
Min
2.0
Max
VCC
Unit
V
Input High Voltage (except EXTAL)
Input Low Voltage (5V Part)
VIL
GND
GND
GND
0.8*(VCC
–
0.8
V
Input Low Voltage (Part Only; PA8-15, PB1, PC5, PC7, TCK)
Input Low Voltage (Part Only; All Other Pins)
EXTAL Input High Voltage
VIL
0.5
V
VIL
0.8
V
VIHC
–
)
VCC + 0.3
-0.8
V
Undershoot
V
Input Leakage Current (All Input Only Pins except for TMS, TDI and TRST)
Vin = 0/5V
Iin
-2.5
-2.5
2.5
µA
µA
Hi-Z (Off-State) Leakage Current (All Noncrystal Outputs and I/O Pins except
TMS,TDI and TRST) Vin = 0/5V
IOZ
-2.5
Signal Low Input Current VIL = 0.8V (TMS, TDI and TRST Pins Only)
Signal High Input Current VIH = 2.0V (TMS, TDI and TRST Pins Only)
IL
-0.5
-0.5
0.5
0.5
mA
mA
IH
Output High Voltage
IOH = -0.8 mA, VCC = 4.75V
VOH
2.4
–
V
AII Noncrystal Outputs Except Open Drain Pins
Output Low Voltage
I
OL = 2.0 mA, CLKO1-2, FREEZE, IPIPE0-1, IFETCH, BKPTO
0.5
0.5
IOL = 3.2 mA, A31-A0, D31-D0, FC3-0, SIZ0-1, PA0, 2, 4, 6, 8-15, PB0-5,
PB8-17, PC0-11, TDO, PERR, PRTY0-3, IOUT0-2, AVECO, AS, CAS3-0,
BLCRO, RAS0-7
VOL
–
–
V
IOL = 5.3 mA, DSACK0-1, R/W, DS, OE, RMC, BG, BGACK, BERR
IOL = 7 mA, TXD1-4
0.5
0.5
0.5
IOL = 8.9 mA, PB6, PB7, HALT, RESET, BR (Output)
Input Capacitance
AII I/O Pins
Cin
20
pF
Load Capacitance (except CLKO1-2)
Load Capacitance (CLKO1-2)
Power
CL
–
–
100
50
pF
pF
V
CLc
VCC
4.75
5.25
7.3
Dynamic Characteristics
The AC specifications presented consist of output delays, input setup and hold times, and signal
skew times. All signals are specified relative to an appropriate edge of the clock and possibly to
one or more other signals.
The measurement of the AC specifications is defined by the waveforms shown in Figure 7-1. To
test the parameters guaranteed by Atmel inputs must be driven to the voltage levels specified in
the figure. Outputs are specified with minimum and/or maximum limits, as appropriate, and are
measured as shown. Inputs are specified with minimum setup and hold times and are measured
as shown. Finally, the measurement for signal-to-signal specifications are shown.
Note that the testing levels used to verify conformance to the AC specifications do not affect the
guaranteed DC operation of the device as specified in the DC electrical characteristics.
14
TS68EN360