TS68EN360
Figure 7-40. PIP Tx (Pulse Mode)
26
25
DATA OUT
24
STBO
(OUTPUT)
23
STBI
(INPUT)
Figure 7-41. Parallel I/O Data-in/Data-out Timing Diagram
CLKO1
(OUTPUT)
DATA IN
29
30
DATA OUT
31
CPU WRITE S4
7.14 Interrupt Controller AC Electrical Specifications
Table 7-13. GND = 0 VDC, TC = -55 to +125°C.The electrical specifications in this document are preliminary.
(See Figure 7-42 and Figure 7-43)
25.0 MHz
33.34 MHz
Number Characteristic
Min
Max
–
Min
Max
–
Unit
ns
35
36
37
38
Port C Interrupt Pulse Width Low (Edge Triggered Mode)
70
70
–
55
55
–
Minimum Time Between Active Edges Port C
Clock High to IOUT Valid (Slave Mode)
Clock High to RQOUT Valid (Slave Mode)
–
–
clk
ns
20
20
17
17
–
–
ns
53
2113B–HIREL–06/05