 浏览型号5962-03A0601VXC的Datasheet PDF文件第34页浏览型号5962-03A0601VXC的Datasheet PDF文件第35页浏览型号5962-03A0601VXC的Datasheet PDF文件第36页浏览型号5962-03A0601VXC的Datasheet PDF文件第37页浏览型号5962-03A0601VXC的Datasheet PDF文件第39页浏览型号5962-03A0601VXC的Datasheet PDF文件第40页浏览型号5962-03A0601VXC的Datasheet PDF文件第41页浏览型号5962-03A0601VXC的Datasheet PDF文件第42页  
AT7908E  
SETUP_RX register and the IntClr bit in the SETUP_3 register (see how to clear inter-  
rupt in the precedent paragraph).  
Operation 5 and 6  
Table 26. write reg 03 H, data =22Hex  
(SETUP_3 register) Resynchronisation jump length = 2 system clock and clear interrupt  
SETUP_3  
RxClr  
0
Reset  
0
IntClr  
0
AbortTx  
0
Txreq  
0
RSJ2  
0
RSJ1  
1
RSJ0  
0
SETUP_3  
RxClr  
0
Reset  
0
IntClr  
0
AbortTx  
0
Txreq  
0
RSJ2  
0
RSJ1  
1
RSJ0  
0
Operation 9  
Table 27. write reg 04 H, data =04Hex  
(SETUP_RX register)Clear rx ok and rx overrun bit of receiver message objects 3  
SETUP_RX  
Reserved  
X
Reserved  
X
Reserved  
X
Reserved  
X
Reserved  
X
Rxclr3  
0
Rxclr2  
0
Rxclr1  
0
SETUP_RX  
Reserved  
X
Reserved  
X
Reserved  
X
Reserved  
X
Reserved  
X
Rxclr3  
0
Rxclr2  
0
Rxclr1  
0
After this operation, the RX3OK bit in STATUS_RX register will be cleared  
STATUS_RX  
STATUS_RX  
reserved  
X
Rxovr3  
0
Rxovr2  
0
Rxovr1  
0
reserved  
x
RXOK3  
1
RXOK2  
0
RXOK1  
0
reserved  
X
Rxovr3  
0
Rxovr2  
0
Rxovr1  
0
reserved  
0
RXOK3  
0
RXOK2  
0
RXOK1  
0
If the MCU doesn’t clear the receiver message object status (principally the Rxok bit )  
and the AT7908E receives a new message on the same message object (for example  
the RX3 message object), the message will be stored in the message object; INT will be  
generated (OVERRUN condition) and the STATUS_RX will be updated as following:  