Technical Reference Notes
AEQ75Y48 Series
(Single Output Quarter Brick)
Basic Operation and Features
INPUT UNDER VOLTAGE LOCKOUT
To prevent any instability to the converter, which may affect the end system, the converter have been designed to turn-on once
VIN is in the voltage range of 34-35.5VDC. Likewise, it has also been programmed to turn-off when VIN drops down to 32-34.5
VDC.
OUTPUT VOLTAGE ADJUST/TRIM
The converter comes with a TRIM pin (PIN 7), which is used to adjust the output by as much as 90% to 110% of its set point.
This is achieved by connecting an external resistor as described below.
To INCREASE the output, external Radj_up resistor
should be connected between TRIM PIN (Pin7) and
-Vout
-Vin
+SENSE PIN (Pin 8). Please refer to Equation (1) for the
-Sense
required external resistance and output adjust
relationship.
Rload
Vadj
+Sense
+Vout
Enable
+Vin
Radj_up
Equation (1):
(
)
5.1 Vo 100 + ∆%
510
Radj_up
−
− 10.2 kΩ
1.225∆%
∆%
Figure 3. External resistor configuration to increase the outputs
To DECREASE the output, external Radj_down resistor
should be connected between TRIM PIN (Pin 7) and
-SENSE PIN (Pin 6). Please refer to Equation (2) for the
required external resistance and output adjust
relationship.
-Vout
-Vin
-Sense
Radj_down
Rload
Vadj
+Sense
+Vout
Enable
+Vin
Equation (2)
510
Radj_down
− 10.2 kΩ
∆%
Figure 4. External resistor configuration to increase the outputs
MODEL: AEQ75Y48 SERIES
JULY 21, 2005 - REVISION 01
SHEET 7 OF 12