Technical Reference Notes
AEQ75Y48 Series
(Single Output Quarter Brick)
Electrical Specifications (continued)
FEATURE SPECIFICATION
Parameter
Device
Symbol
Min
Typ
Max
Unit
Output Enable ON/OFF
Negative Enable ("N" suffix)
Enable Pin voltage for Module OFF
Module ON
N
suffix
-
-
2.95
0
-
-
20.0
0.8
V
V
Positive Enable (No suffix)
Enable Pin voltage for Module ON
Module OFF
No
suffix
-
-
0
2.95
-
-
0.8
20.0
V
V
Enable Pin current
Module at ON State
Module at OFF State (Leakage)
All
-
-
-
-
-
-
1
50
mA
µA
Output Voltage Remote Sensing7, 9
Output Voltage Trim Range8, 9
All
All
-
-
-
10
%VO
%VO
90
110
Note: 7. The sense pins can be used to compensate for any voltage drops (per indicated max limits) that may
occur along the connection between the output pins to the load. Pin 8 (+Sense) and Pin 6 (-Sense) should
be connected to Pin 9 (+Vout) and Pin 5 (Return) respectively at the point where regulation is desired.
8. Refer to Equation (1) and (2) and Figures 3 and 4 for the Output Trim Adjust configuration.
9. The combination of remote sense and Trim adjust cannot exceed 110% of VO, NOM
.
ISOLATION SPECIFICATION
Parameter
Isolation Capacitance
Isolation Resistance
Device
All
All
Min
-
10
Typ
2.70
-
Max
-
-
Unit
nF
MW
MTBF
Telcordia SR332 (Parts Stress)
1,029,514
Hrs
TA = 40°C; IO = 30A; Airflow = 200LFM
SAFETY APPROVAL
The AEQ75Y48 series have been certified through:
·
·
UL + cUL 60950, Third Edition - Recognized
EN 60950 through TUV-PS
MODEL: AEQ75Y48 SERIES
JULY 21, 2005 - REVISION 01
SHEET 5 OF 12