Technical Reference Notes
AEQ75Y48 Series
(Single Output Quarter Brick)
Electrical Specifications (continued)
OUTPUT SPECIFICATIONS
Parameter
Device
Symbol
Min
Typ
Max
Unit
Efficiency
All
88
89
-
%
VIN = VIN-NOM; TA=25°C
h
Turn-On Response Time
VIN = VIN-MIN to VIN-MAX
Switching Frequency
All
All
-
-
-
-
-
15
520
ms
KHz
440
Dynamic Response:
CO = 0uF
-
0.09
0.1
1.1
DIO/Dt
A/ms
Peak Deviation
Load Change from IO = 50% to 75% of
%Vo,SET
ms
Vpk
ts
-
-
-
-
4
8
All
IO, Max
:
Settling Time to VO, Nom
100
4
300
8
%Vo,SET
ms
Peak Deviation
Load Change from IO = 50% to 25% of
Vpk
ts
All
All
IO, Max
:
100
300
Settling Time to output voltage setpoint
tolerance – Vo,SET
Output Overshoot
-
-
-
4
%Vo
at T-on / T-off
Note: 1. An input line fuse is recommended for use.
2. External input capacitance required. See Input Ripple Current test measurement setup on Figure 1.
3. Refer to Figure 2 for output ripple measurement setup.
4. Appropriate Thermal Derating applies. See Figure 6.
5. Over current and over voltage protections are all in auto recovery mode. The converter will shutdown
during fault condition then will attempt to auto restart.
6. Output of the module will be terminated once the operating temperature reaches the OTP threshold.
Normal operation resumes once the temperature falls below the OTP threshold.
MODEL: AEQ75Y48 SERIES
JULY 21, 2005 - REVISION 01
SHEET 4 OF 12