AX88196
Local CPU BUS MAC Controller
6.0 Electrical Specification and Timings
6.1 Absolute Maximum Ratings
Description
SYM
Min
Max
Units
°C
°C
V
V
V
V
V
V
°C
Operating Temperature
Storage Temperature
Supply Voltage
Supply Voltage
Input Voltage
Ta
Ts
0
+85
-55
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-55
+150
HVdd
LVdd
HVin
LVin
HVout
LVin
Tl
+6
+4.6
HVdd+0.5
LVdd+0.5
HVdd+0.5
LVdd+0.5
+220
Output Voltage
Lead Temperature (soldering 10 seconds maximum)
Note : Stress above those listed under Absolute Maximum Ratings may cause permanent damage to the device.
Exposure to Absolute Maximum Ratings conditions for extended period, adversely affect device life and reliability.
Note : The power supply voltages must always fulfill HVdd >= LVdd inequality.
6.2 General Operation Conditions
Description
SYM
Ta
Min
Tpy
Max
Units
°C
V
V
V
Operating Temperature
Supply Voltage
0
25
+75
HVdd +4.75V
LVdd +2.70
+3.00
+5.00V
+3.00
+3.30
+5.25V
+3.30
+3.60
Note : The power supply voltages must always fulfill HVdd >= LVdd inequality.
6.3 DC Characteristics
(Vdd=5.0V, Vss=0V, Ta=0°C to 75°C)
Description
SYM
Vil
Vih
Vol
Voh
Iil
Min
Tpy
Max
Units
V
V
V
V
Low Input Voltage
High Input Voltage
-
2
-
0.8
-
0.4
-
+1
+1
Low Output Voltage
High Output Voltage
Input Leakage Current
Output Leakage Current
Vdd-0.4
-1
-1
uA
uA
Iol
(Vdd=3.0V to 3.6V, Vss=0V, Ta=0°C to 75°C)
Description
Low Input Voltage
High Input Voltage
Low Output Voltage
High Output Voltage
Input Leakage Current
Output Leakage Current
SYM
Min
Tpy
Max
Units
V
V
V
V
Vil
Vih
Vol
Voh
Iil
-
1.9
-
0.8
-
0.4
-
+1
+1
Vdd-0.4
-1
-1
uA
uA
Iol
Description
Power Consumption (Dual power)
SYM
Min
Tpy
Max
Units
mA
mA
DPt5v
DPt3v
SPt3v
20
32
50
Power Consumption (Single power 3.3V)
mA
25