Analog Power
AM40N20-180P
Typical Electrical Characteristics
10
2.5
VDS = 100V
9
ID = 10A
8
7
6
5
4
3
2
1
0
2
1.5
1
0.5
-50 -25
0
25
50
75 100 125 150
0
3
6
9
12
15
Qg - Total Gate Charge (nC)
TJ -JunctionTemperature(°C)
7. Gate Charge
8. Normalized On-Resistance Vs
Junction Temperature
1000
100
10
175
150
125
100
75
10 uS
100 uS
1 mS
10 mS
100 mS
1 SEC
10 SEC
100 SEC
DC
1
50
0.1
0.01
Idm limit
25
Limited by
RDS
0
0.1
1
10
100
1000
0.001 0.01
0.1
1
10
100
1000
VDS Drain to Source Voltage (V)
t1 TIME (SEC)
9. Safe Operating Area
10. Single Pulse Maximum Power Dissipation
1
0.1
D = 0.5
0.2
0.1
RθJA(t) = r(t) + RθJA
RθJA = 62.5 °C /W
0.05
P(pk)
t1
0.02
t2
Single Pulse
0.01
TJ - TA = P * RθJA(t)
Duty Cycle, D = t1 / t2
0.001
0.0001
0.001
0.01
0.1
1
10
100
1000
t1 TIME (sec)
11. Normalized Thermal Transient Junction to Ambient
© Preliminary
4
Publication Order Number:
DS_AM40N20-180P_1A