Analog Power
AM40N20-180P
Electrical Characteristics
Parameter
Symbol
Test Conditions
Static
Min
Typ
Max
Unit
VGS(th)
IGSS
VDS = VGS, ID = 250 uA
VDS = 0 V, VGS = ±20 V
VDS = 160 V, VGS = 0 V
VDS = 160 V, VGS = 0 V, TJ = 55°C
VDS = 5 V, VGS = 10 V
VGS = 10 V, ID = 10 A
VGS = 5.5 V, ID = 8 A
VDS = 15 V, ID = 10 A
IS = 10 A, VGS = 0 V
Dynamic
Gate-Source Threshold Voltage
Gate-Body Leakage
1
V
±100
1
nA
IDSS
ID(on)
Zero Gate Voltage Drain Current
On-State Drain Current
uA
A
25
34
180
340
rDS(on)
Drain-Source On-Resistance
mΩ
gfs
Forward Transconductance
Diode Forward Voltage
25
S
V
VSD
0.86
Qg
Qgs
Qgd
td(on)
tr
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
Turn-On Delay Time
Rise Time
7
3.1
3.3
9
VDS = 100 V, VGS = 4.5 V,
ID = 10 A
nC
ns
VDS = 100 V, RL = 10 Ω,
ID = 10 A,
VGEN = 10 V, RGEN = 6 Ω
14
33
26
948
80
54
td(off)
tf
Turn-Off Delay Time
Fall Time
Ciss
Coss
Crss
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
VDS = 15 V, VGS = 0 V, f = 1 MHz
pF
Notes
a. Pulse test: PW <= 300us duty cycle <= 2%.
b. Guaranteed by design, not subject to production testing.
Analog Power (APL) reserves the right to make changes without further notice to any products herein. APL makes no warranty,
representation or guarantee regarding the suitability of its products for any particular purpose, nor does APL assume any liability arising out
of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special,
consequential or incidental damages. “Typical” parameters which may be provided in APL data sheets and/or specifications can and do vary
in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each
customer application by customer’s technical experts. APL does not convey any license under its patent rights nor the rights of others. APL
products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other
applications intended to support or sustain life, or for any other application in which the failure of the APL product could create a situation
where personal injury or death may occur. Should Buyer purchase or use APL products for any such unintended or unauthorized application,
Buyer shall indemnify and hold APL and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs,
damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated
with such unintended or unauthorized use, even if such claim alleges that APL was negligent regarding the design or manufacture of the part.
APL is an Equal Opportunity/Affirmative Action Employer.
© Preliminary
2
Publication Order Number:
DS_AM40N20-180P_1A