A25L16P Series
Table 10. DC Characteristics
Symbol
Parameter
Input Leakage Current
Output Leakage Current
Test Condition
Min.
Max.
± 2
Unit
µA
ILI
ILO
± 2
µA
ICC1
ICC2
Standby Current
10
10
µA
µA
S
S
= VCC, VIN = VSS or VCC
= VCC, VIN = VSS or VCC
Deep Power-down Current
C= 0.1VCC / 0.9.VCC at 50MHz, DO = open
C= 0.1VCC / 0.9.VCC at 33MHz, DO = open
16
12
mA
mA
ICC3
Operating Current (READ)
ICC4
ICC5
ICC6
ICC7
Operating Current (PP)
Operating Current (WRSR)
Operating Current (SE)
Operating Current (BE)
15
15
15
15
mA
mA
mA
mA
S
S
S
S
= VCC
= VCC
= VCC
= VCC
VIL
VIH
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
–0.5
0.3VCC
VCC+0.4
0.4
V
V
V
V
0.7VCC
VOL
VOH
IOL = 1.6mA
IOH = –100µA
VCC–0.2
Note: 1. This is preliminary data at 85°C
Table 11. Instruction Times
Symbol
Alt.
Parameter
Write Status Register Cycle Time
Page Program Cycle Time
Sector Erase Cycle Time
Min.
Typ.
100
3
Max.
300
5
Unit
ms
ms
s
tW
tPP
tSE
1
3
tBE
Bulk Erase Cycle Time
20
40
s
Note: 1. At 85°C
2. This is preliminary data
Table 12. AC Measurement Conditions
Symbol
Parameter
Min.
Max.
Unit
CL
Load Capacitance
30
pF
ns
V
Input Rise and Fall Times
Input Pulse Voltages
5
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
VCC / 2
Input Timing Reference Voltages
Output Timing Reference Voltages
V
V
Note: Output Hi-Z is defined as the point where data out is no longer driven.
PRELIMINARY (April, 2007, Version 0.6)
28