8.0 Recommended Operating Conditions at 25°C
Table 10 lists the recommended operating conditions common to all three modules. Table 11 lists the recommended operating
conditions particular to each of the three LED light sources.
Table 10: Recommended Operating Conditions at 25°C, Common to all Three Modules
Parameter
Power supply
Symbol
Vdd (positive)
Vn (negative)
Idd (positive)
In (negative)
Vih
Min.
4.5
-10
60
19
Vdd - 1.0
0
0.518
25
Typ.
5.0
-5
66
20
Max.
5.5
-4.0
75
Units
V
V
mA
mA
V
V
MHz
%
21
Input voltage (high level)
Input voltage (low level)
Clock frequency (1)
Clock pulse high duty cycle
Clock pulse high duration
Integration time (1)
Vdd -0.5
Vdd
0.6
5.5
75
Vil
Fclk
Duty
Pwck
Tint
Top
50
46
82
ns
150
25
µs
Operating temperature
50
°C
Table 11: Recommended Operating Conditions at 25°C, for each LED
LED Light Source
660nm Red LED
Parameter
VLED
Min.
Typ.
5.0
480
Max.
5.5
550
Units
Volts
mA
ILED
525nm Green LED
VLED
ILED
5.0
TBD
5.5
TBD
Volts
mA
Low-power Yellow-Green LED
VLED
ILED
5.0
TBD
5.5
TBD
Volts
mA
Note:
1.
The maximum clock speed is limited by the modules light source power, due to the low light power associated with LED’s. The minimum clock speed is determined
by the longest tolerable integration time. Because of the leakage current build up, the integration time is recommended to be no greater than 10ms.
AMI Semiconductor – Jan. 06, M-20493-001