 浏览型号PALCE16V8H-5JC的Datasheet PDF文件第18页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第19页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第20页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第21页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第22页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第23页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第24页浏览型号PALCE16V8H-5JC的Datasheet PDF文件第25页  
 
AMD  
TYPICAL THERMAL CHARACTERISTICS  
/4 Devices (PALCE16V8H-10/4)  
Measured at 25°C ambient. These parameters are not tested.  
Typ  
Parameter  
Symbol  
Parameter Description  
PDIP  
25  
PLCC  
22  
Unit  
θjc  
Thermal Impedance, Junction to Case  
Thermal Impedance, Junction to Ambient  
Thermal Impedance, Junction to Ambient with Air Flow  
°C/W  
°C/W  
°C/W  
°C/W  
°C/W  
°C/W  
θja  
71  
64  
θjma  
200 Ifpm air  
400 Ifpm air  
600 Ifpm air  
800 Ifpm air  
61  
55  
55  
51  
51  
47  
47  
45  
/5 Devices (PALCE16V8H-7/5)  
Measured at 25°C ambient. These parameters are not tested.  
Typ  
Parameter  
Symbol  
Parameter Description  
PDIP  
29  
70  
64  
58  
53  
X
PLCC  
23  
Unit  
°C/W  
°C/W  
°C/W  
°C/W  
°C/W  
°C/W  
θjc  
Thermal Impedance, Junction to Case  
Thermal Impedance, Junction to Ambient  
Thermal Impedance, Junction to Ambient with Air Flow  
θja  
61  
θjma  
200 Ifpm air  
400 Ifpm air  
600 Ifpm air  
800 Ifpm air  
53  
47  
44  
X
Plastic θjc Considerations  
The data listed for plastic θjc are for reference only and are not recommended for use in calculating junction temperatures. The  
heat-flow paths in plastic-encapsulated devices are complex, making the θjc measurement relative to a specific location on the  
package surface. Tests indicate this measurement reference point is directly below the die-attach area on the bottom center of the  
package. Furthermore, θjc tests on packages are performed in a constant-temperature bath, keeping the package surface at a  
constant temperature. Therefore, the measurements can only be used in a similar environment.  