D A T A S H E E T
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
20 ns
20 ns
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . . . . . . –65°C to +125°C
0.0 V
Voltage with Respect to Ground
–0.5 V
–2.0 V
VCC (Note 1) . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
A9, OE#,
and RESET# (Note 2) . . . . . . . . . . . . . . . .–0.5 V to +11.0 V
20 ns
All other pins (Note 1) . . . . . . . . . . . . . –0.5 V to VCC+0.5 V
Output Short Circuit Current (Note 3) . . . . . . . . . . . 100 mA
Figure 7. Maximum Negative Overshoot Waveform
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage
transitions, input or I/O pins may overshoot VSS to –2.0 V for
periods of up to 20 ns. See Figure 7. Maximum DC voltage on
input or I/O pins is VCC +0.5 V. During voltage transitions, input
or I/O pins may overshoot to VCC +2.0 V for periods up to 20 ns.
See Figure 8.
20 ns
2. Minimum DC input voltage on pins A9, OE#, and RESET# is –0.5
V. During voltage transitions, A9, OE#, and RESET# may
overshoot VSS to –2.0 V for periods of up to 20 ns. See.
Maximum DC input voltage on pin A9 is +11.0 V which may
overshoot to 12.5 V for periods up to 20 ns.
VCC
+2.0 V
VCC
+0.5 V
3. No more than one output may be shorted to ground at a time.
Duration of the short circuit should not be greater than one
second.
2.0 V
20 ns
20 ns
Stresses above those listed under “Absolute Maximum Ratings” may
cause permanent damage to the device. This is a stress rating only;
functional operation of the device at these or any other conditions
above those indicated in the operational sections of this data sheet is
not implied. Exposure of the device to absolute maximum rating
conditions for extended periods may affect device reliability.
Figure 8. Maximum Positive Overshoot Waveform
V
Supply Voltages
CC
OPERATING RANGES
Commercial (C) Devices
VCC for full voltage range . . . . . . . . . . . . . +1.65 V to +2.2 V
VCC for regulated voltage range. . . . . . . . +1.70 V to +2.2 V
Ambient Temperature (TA) . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Note: Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
Ambient Temperature (TA) . . . . . . . . . . . . . . –40°C to +85°C
January 23, 2007 Am29SL400C_00_A6
Am29SL400C