SONET/SDH OC-12 TO OC-48 MUX/DEMUX
S3045
Figure 18. AC Transmitter Output Timing Diagram
311CLKOUTP
tS
311
tH
311
311DATOUT[7:0]
READP/N
Notes:
1. When a set-up time is specified on differential LVDS signals between an input and a clock, the set-up time is the time in nanoseconds from
the cross-over point of the input to the cross-over point of the clock.
2. When a hold time is specified on differential LVDS signals between an input and a clock, the hold time is the time in nanoseconds from the
cross-over point of the clock to the cross-over point of the input.
Table 14. Transmitter Output Timing Characteristics
Symbol
Description
Min
33
Max Units
311CLKOUT Duty Cycle
67
%
ns
ns
tS311
tH311
311DATOUT[7:0] Set-up Time w.r.t. 311CLKOUTP
311DATOUT[7:0] Hold Time w.r.t. 311CLKOUTP
0.65
0.55
Table 15. Transmitter Input Timing Characteristics
Symbol Description
311TCLK
Min
Max Units
55
311TCLK Duty Cycle
45
%
27
December 13, 1999 / Revision E