1–2  
Chapter 1: Cyclone III Device Data Sheet  
Electrical Characteristics  
Table 1–1. Cyclone III Devices Absolute Maximum Ratings  
Symbol Parameter  
IOUT DC output current, per pin  
VESDHBM  
(Note 1) (Part 2 of 2)  
Min  
Max  
Unit  
–25  
40  
mA  
Electrostatic discharge voltage using the human  
body model  
2000  
500  
V
V
Electrostatic discharge voltage using the  
charged device model  
VESDCDM  
TSTG  
TJ  
Storage temperature  
–65  
–40  
150  
125  
°C  
°C  
Operating junction temperature  
Note to Table 1–1:  
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the  
power supply.  
Maximum Allowed Overshoot or Undershoot Voltage  
During transitions, input signals may overshoot to the voltage listed in Table 1–2 and  
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods  
shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and  
the duration of the overshoot voltage as a percentage over the lifetime of the device.  
The maximum allowed overshoot duration is specified as percentage of high-time  
over the lifetime of the device.  
1
A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to  
4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime  
of 10 years, this amounts to 10.74/10ths of a year.  
Cyclone III Device Handbook, Volume 2  
© January 2010 Altera Corporation