 浏览型号EP3C16Q144C6ES的Datasheet PDF文件第46页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第47页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第48页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第49页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第51页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第52页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第53页浏览型号EP3C16Q144C6ES的Datasheet PDF文件第54页  
3–16
Chapter 3: Memory Blocks in the Cyclone III Device Family
Design Considerations
Same-Port Read-During-Write Mode
This mode applies to a single-port RAM or the same port of a true dual-port RAM. In
the same port read-during-write mode, there are two output choices:
New Data
mode
(or flow-through) and
Old Data
mode. In
New Data
mode, new data is available on
the rising edge of the same clock cycle on which it was written. In
Old Data
mode, the
RAM outputs reflect the old data at that address before the write operation proceeds.
When using
New Data
mode together with
byteena,
you can control the output of the
RAM. When
byteena
is high, the data written into the memory passes to the output
(flow-through). When
byteena
is low, the masked-off data is not written into the
memory and the old data in the memory appears on the outputs. Therefore, the
output can be a combination of new and old data determined by
byteena.
and
show sample functional waveforms of same port
read-during-write behavior with both
New Data
and
Old Data
modes, respectively.
Figure 3–15. Same Port Read-During Write: New Data Mode
clk_a
wren_a
rden_a
address_a
a0
a1
data_a
A
B
C
D
E
F
q_a
(asynch)
A
B
C
D
E
F
Figure 3–16. Same Port Read-During-Write: Old Data Mode
clk_a
wren_a
rden_a
address_a
a0
a1
data_a
A
B
C
D
E
F
q_a
(asynch)
a0(old data)
A
B
a1(old data)
D
E
Mixed-Port Read-During-Write Mode
This mode applies to a RAM in simple or true dual-port mode, which has one port
reading and the other port writing to the same address location with the same clock.
Cyclone III Device Handbook
Volume 1