Chapter 5: Clock Networks and PLLs in the Cyclone III Device Family  
PLL Reconfiguration  
Keep the secondary PLL in a reset state until the primary PLL has locked to ensure  
the phase settings are correct on the secondary PLL.  
You cannot connect either of the inclkports of any PLLs in the cascaded scheme  
to clock outputs from PLLs in the cascaded scheme.  
PLL Reconfiguration  
PLLs use several divide counters and different VCO phase taps to perform frequency  
synthesis and phase shifts. In Cyclone III device family PLLs, you can reconfigure  
both counter settings and phase shift the PLL output clock in real time. You can also  
change the charge pump and loop filter components, which dynamically affects PLL  
bandwidth. You can use these PLL components to update the output clock frequency,  
PLL bandwidth, and phase shift in real time, without reconfiguring the entire FPGA.  
The ability to reconfigure the PLL in real time is useful in applications that might  
operate at multiple frequencies. It is also useful in prototyping environments,  
allowing you to sweep PLL output frequencies and adjust the output clock phase  
dynamically. For instance, a system generating test patterns is required to generate  
and send patterns at 75 or 150 MHz, depending on the requirements of the device  
under test. Reconfiguring PLL components in real time allows you to switch between  
two such output frequencies in a few microseconds.  
You can also use this feature to adjust clock-to-out (tCO) delays in real time by  
changing the PLL output clock phase shift. This approach eliminates the need to  
regenerate a configuration file with the new PLL settings.  
PLL Reconfiguration Hardware Implementation  
The following PLL components are configurable in real time:  
Pre-scale counter (N)  
Feedback counter (M)  
Post-scale output counters (C0-C4  
)
Dynamically adjust the charge pump current (  
ICP) and loop filter components  
(R, C) to facilitate on-the-fly reconfiguration of the PLL bandwidth  