AS29F400
Preliminary information
®
Recommended operating conditions
Parameter
Symbol
Min
+4.5
0
Typ
5.0
0
Max
+5.5
0
Unit
V
V
V
V
V
CC
SS
Supply voltage
Input voltage
V
2.0
–0.5
-
V
+ 0.5
CC
V
V
IH
IL
-
0.8
Absolute maximum ratings
Parameter
Symbol
Min
–2.0
–2.0
-0.5
–55
–65
-
Max
Unit
V
Input voltage (Input or DQ pin)
Input voltage (A9 pin, OE, RESET)
Power supply voltage
V
V
V
+7.0
+13.0
+5.5
+125
+125
200
IN
IN
V
V
CC
Operating temperature
T
T
°C
°C
mA
OPR
STG
OUT
Storage temperature (plastic)
Short circuit output current
I
Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions outside those indicated in the operational sections of this specification is not implied. Exposure to absolute max-
imum rating conditions for extended periods may affect reliability.
TSOP pin capacitance
Symbol
Parameter
Test setup
Typ
6
Max
7.5
12
Unit
pF
C
C
C
Input capacitance
Output capacitance
Control pin capacitance
V
V
V
= 0
IN
IN
OUT
= 0
= 0
8.5
8
pF
OUT
IN2
10
pF
IN
SO pin capacitance
Symbol
Parameter
Test setup
Typ
6
Max
7.5
12
Unit
pF
C
C
C
Input capacitance
Output capacitance
Control pin capacitance
V
V
V
= 0
IN
IN
OUT
= 0
= 0
8.5
8
pF
OUT
IN2
10
pF
IN
Data retention
Parameter
Temp.(°C) Min
Unit
150°
125°
10
20
years
years
Minimum pattern data retention time
17