欢迎访问ic37.com |
会员登录 免费注册
发布采购

UCN5800L 参数 Datasheet PDF下载

UCN5800L图片预览
型号: UCN5800L
PDF下载: 下载PDF文件 查看货源
内容描述: 采用BiMOS II锁存驱动程序 [BiMOS II LATCHED DRIVERS]
分类和应用: 外围驱动器驱动程序和接口接口集成电路光电二极管
文件页数/大小: 12 页 / 118 K
品牌: ALLEGRO [ ALLEGRO MICROSYSTEMS ]
 浏览型号UCN5800L的Datasheet PDF文件第1页浏览型号UCN5800L的Datasheet PDF文件第2页浏览型号UCN5800L的Datasheet PDF文件第3页浏览型号UCN5800L的Datasheet PDF文件第5页浏览型号UCN5800L的Datasheet PDF文件第6页浏览型号UCN5800L的Datasheet PDF文件第7页浏览型号UCN5800L的Datasheet PDF文件第8页浏览型号UCN5800L的Datasheet PDF文件第9页  
5800AND 5801  
BiMOS II  
LATCHED DRIVERS  
UCN5801A  
CLEAR  
F
STROBE  
OUTPUT  
ENABLE  
1
2
3
4
22  
21  
20  
19  
18  
17  
16  
CLEAR  
A
C
G
B
B
C
C
A
B
OUTPUT  
ENABLE  
STROBE  
V
SUPPLY  
DD  
G
IN  
N
OUT  
1
IN  
1
E
E
D
IN  
2
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
2
3
4
5
6
7
8
OUT  
N
5
6
IN  
3
Dwg. No. A-10,895A  
TIMING CONDITIONS  
IN  
4
(Logic Levels are VDD and Ground)  
7
8
IN  
5
IN  
6
15  
A. Minimum Data Active Time Before Strobe Enabled  
(Data Set-Up Time) ..........................................................50 ns  
IN  
7
9
14  
13  
12  
10  
IN  
8
B. Minimum Data Active Time After Strobe Disabled  
(Data Hold Time) .............................................................. 50 ns  
11  
COMMON  
Dwg. PP-015  
GROUND  
C. Minimum Strobe Pulse Width ..................................................125 ns  
D. Typical Time Between Strobe Activation and  
Output On to Off Transition ............................................500 ns  
E. Minimum Time Between Strobe Activation and  
Output Off to On Transition ............................................500 ns  
UCN5801LW  
F. Minimum Clear Pulse Width ....................................................300 ns  
G.Minimum Data Pulse Width .....................................................225 ns  
OUTPUT  
ENABLE  
1
2
3
4
24  
23  
22  
21  
20  
19  
18  
CLEAR  
Information present at an input is transferred to its latch when the  
STROBE is high. A high CLEAR input will set all latches to the output  
OFF condition regardless of the data or STROBE input levels. A high  
OUTPUT ENABLE will set all outputs to the OFF condition, regardless  
of any other input conditions. When the OUTPUT ENABLE is low, the  
outputs depend on the state of their respective latches.  
STROBE  
V
SUPPLY  
DD  
OUT  
1
IN  
1
IN  
2
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
2
3
4
5
6
7
8
5
6
IN  
3
IN  
4
TRUTH TABLE  
7
8
IN  
5
OUT  
N
OUTPUT  
ENABLE  
IN  
6
17  
IN  
STROBE  
CLEAR  
t-1  
t
N
IN  
7
9
16  
15  
14  
0
1
X
X
X
X
1
1
X
X
0
0
0
0
1
X
0
0
0
0
X
1
0
0
X
X
X
X
ON  
OFF  
OFF  
ON  
OFF  
OFF  
ON  
10  
IN  
8
11  
12  
COMMON  
GROUND  
NO  
NO  
NC  
13  
NC  
CONNECTION  
CONNECTION  
OFF  
Dwg. PP-015-1  
X = irrelevant.  
t-1 = previous output state.  
t = present output state.  
115 Northeast Cutoff, Box 15036  
Worcester, Massachusetts 01615-0036 (508) 853-5000