FUNCTIONAL DESCRIPTION  
D7 – D10 Fast Decay Time. A four-bit word sets the  
fast-decay portion of the fixed-off time for the internal  
PWM control circuitry. This will only have impact if the  
mixed-decay mode is selected (via bit D17 and the MODE  
input terminal). For tfd > toff, the device will effectively  
operate in the fast-decay mode. The fast decay portion is  
defined by  
Serial Interface. The A3958 is controlled via a 3-wire  
(clock, data, strobe) serial port. The programmable  
functions allow maximum flexibility in configuring the  
PWM to the motor drive requirements. The serial data is  
clocked in starting with D19.  
Bit Function  
D0 Blank Time LSB  
D1 Blank Time MSB  
D2 Off Time LSB  
tfd = (8[1 + N]/fosc) - 1/fosc  
where N = 0 … 15  
D3 Off Time Bit 1  
D4 Off Time Bit 2  
D5 Off Time Bit 3  
D6 Off Time MSB  
For example, with an oscillator frequency of 4 MHz, the  
fast decay time will be adjustable from 1.75 µs to  
31.75 µs in increments of 2 µs.  
D11 Synchronous Rectification Mode. The active  
mode prevents reversal of load current by turning off  
synchronous rectification when a zero current level is  
detected. The passive mode will allow reversal of current  
but will turn off the synchronous rectifier circuit if the  
load current inversion ramps up to the current limit set by  
VREF/RS.  
D7 Fast Decay Time LSB  
D8 Fast Decay Time Bit 1  
D9 Fast Decay Time Bit 2  
D10 Fast Decay Time MSB  
D11 Sync. Rect. Mode  
D12 Sync. Rect. Enable  
D13 External PWM Mode  
D14 Enable  
D11  
Mode  
D15 Phase  
0
1
Active  
Passive  
D16 Reference Range Select  
D17 Internal PWM Mode  
D18 Test Use Only  
D19 Sleep Mode  
D12 Synchronous Rectification Enable.  
D12 Synchronous Rect.  
D0 – D1 Blank Time. The current-sense comparator is  
blanked when any output driver is switched on, according  
to the table below. fosc is the oscillator input frequency.  
0
1
Disabled  
Enabled  
D13 External PWM Decay Mode. Bit D13 determines  
the current-decay mode when using ENABLE chopping  
for external PWM current control.  
D1  
D0  
Blank Time  
0
0
1
1
0
1
0
1
4/fosc  
6/fosc  
12/fosc  
24/fosc  
D13  
0
1
Mode  
Fast  
Slow  
D2 – D6 Fixed-Off Time. A five-bit word sets the  
fixed-off time for internal PWM current control. The off  
time is defined by  
D14 Enable Logic. Bit D14, in conjunction with  
ENABLE, determines if the output drivers are in the  
chopped (OFF)(ENABLE = D14) or ON (ENABLE ≠  
D14) state.  
t
off = (8[1 + N]/fosc) - 1/fosc  
where N = 0 … 31  
ENABLE D14  
Mode  
Chopped  
On  
On  
Chopped  
For example, with an oscillator frequency of 4 MHz, the  
off time will be adjustable from 1.75 µs to 63.75 µs in  
increments of 2 µs.  
0
1
0
1
0
0
1
1
www.allegromicro.com  