ASAHI KASEI  
[AK4140]  
„ Soft Mute Operation (default = Mute)  
When the SMUTE bit goes to “1”, the output signal is attenuated from 0dB to -dB during 768 LRCK cycles. When the  
SMUTE bit returns to “0”, the mute is cancelled and the attenuation gradually changes to 0dB during 768 LRCK cycles.  
If the soft mute is cancelled before attenuating to -, the attenuation is discontinued and returns to 0dB. This return takes  
the same number of clock cycles as the point at which the soft mute cancel was initiated, i.e. if 500 clock cycles passed  
and then a soft mute cancel was issued, it will take 500 clock cycles to return to 0dB. The soft mute is used primarily when  
changing the signal source.  
SMUTE  
0dB  
Attenuation Level  
at SDTO  
-
dB  
(2)  
(1)  
(1)  
Notes:  
(1) Transition time. 768 LRCK cycles (768/fs).  
(2) If the soft mute is cancelled before attenuating to -after starting the operation, the attenuation is discontinued  
and returned to 0dB by the same number of clock cycles.  
Figure 13. Soft Mute  
MS0547-E-01  
2007/03  
- 28 -  