7. Shutdown Control  
7.1 Shutdown Operation  
The AK2572 can be put into the shutdown condition by setting TXDIS-pin to “H”.  
The condition for shutdown in Table 7-1, and operation during shutdown in Table 7-2 are shown.  
Table 7-1 Shutdown Condition  
TXDIS RE_SFP_SET TXFAULT  
Operation  
Normal operation  
Shutdown  
Normal operation  
Shutdown  
Note  
0
0
0
1
x
x
Operation at TXFAULT detection for SFP support  
Shutdown request via TXDIS-pin  
1
x
1
Table 7-2 Operation during Shutdown  
Function  
I-DAC1,2 output Hi-Z  
V-DAC3 output 0.2 V [Max.]  
Operation during Shutdown  
Note  
[*]  
[*]  
Based on the detected temperature, temperature compensation data for I-DAC  
and V-DAC are updated. But I-DAC output is in Hi-Z state and V-DAC output  
voltage is 0.2 V [Max.]  
APC  
Feed Forward  
During shutdown requested via TXDIS, a value just before the shutdown is held.  
During shutdown requested by TXFAULT (RE_SFP_SET“0”), a value just  
before the shutdown is held and it is reset at shutdown release by TXDIS.  
Normal operation (CURRALM is set to “ Disabled output“ state)  
At RE_SFP_SET =”0”, a value just before the shutdown is held.  
At RE_SFP_SET =”1”, logical “OR” function of the selected ALMs is output.  
APC  
Feed Back  
ALM  
TXFAULT  
[*] DAC output (I-DAC1 or V-DAC3), which is selected as EXTRA_DAC, is not shutdown.  
7.2 Operation at Shutdown Release  
Since the AK2572 continues its temperature detection and APC feed forward operation even during the  
shutdown, current value that is set by Feed Forward function is temperature compensated even if any  
temperature difference occurs before or after the shutdown.  
On the other hand, whether a value just before the shutdown is held or an initial value is set as APC Feed Back  
data (R_APC_FB) can be selected by RE_TEMP_DET setting. When to hold a value just before the shutdown, a  
temperature at shutdown release (R_TEMP) and a temperature just before shutdown (to be retained at  
R_TEMP_STDW) are compared. If the difference is larger than the set value (RE_TEMP_WIN), namely, when  
the following relation is satisfied, ABS(R_TEMP–R_TEMP_STDW)RE_TEMP_WIN, a function to set  
R_APC_FB to initial value is activated so that an excess power emission of LD and a turn-on delay of LD are  
eliminated. As initialization of R_APC_FB is executed with being based on the detected temperature just before  
shutdown release, a turn-on operation is accelerated if the initial setting function of APC_FB is selected  
(RE_APC_INIT_SET“1”). In Table 7-3, R_APC_FB values at shutdown release are listed.  
Table 7-3 R_APC_FB Values at Shutdown Release  
RE_  
TX-  
RE_  
Temperature  
R_APC_FB  
Note  
SFP_SET FAULT TEMP_DET difference  
0
1
x
0
1
x
x
0
1
Initial value  
Held value  
Initial value  
Initial value  
Initial value  
Held value  
Initial value  
0
1
x
ABS(TEMP–TEMP_STDW)TEMP_WIN  
ABS(TEMP–TEMP_STDW)TEMP_WIN  
Shutdown released by TXDIS  
0
1
x
0
ABS(TEMP–TEMP_STDW)TEMP_WIN  
ABS(TEMP–TEMP_STDW)TEMP_WIN  
1