ASAHI KASEI  
[AK2572]  
6. Alarm Function  
In Table 6-1, the outline of the AK2572 Alarm (ALM) functions such as TEMPALM, OPTALM, CURRALM,  
EXTALM1 and EXTALM2, and TXFAULT output function where alarms to be selected by EEPROM/Register  
setting are logically OR-ed, are listed.  
Table 6-1 ALM Function Outlines  
Detect time  
ALM  
Condition to output alarm  
Note  
[Typ.]  
When detected temperature equivalent value  
exceeds ALM set value (E_TEMPALM)  
When monitor PD input voltage becomes lower  
than ALM set value (RE_OPTALM)  
When a current to be set to DAC exceeds ALM set  
value (RE_CURRALM_BIAS / MOD)  
Temp. sense period=64ms  
Set by RE_TEMPALM_SET  
Holding APC FB value  
TEMPALM  
OPTALM  
CURRALM  
64 ms  
5 μs [*]  
125 μs  
1 μs  
Set by RE_OPTALM_SET  
Set by RE_CURRALM_SET  
EXTALM1 When same polarity ALM signal is input on  
EXTALM2 EXTALM1/2-pin as set by RE_EXTALM1/2_POL  
Set by RE_EXTALM1_SET  
Set by RE_EXTALM2_SET  
Automatically shutdown  
when any target alarm is  
detected and RE_SFP_SET  
”0”  
When any of the ALMs is detected as target alarms  
available on TXFAULT-pin output which are set by  
EEPROM / Register setting (Refer to note above in  
this table)  
Depend on  
the detected  
target alarm  
TXFAULT  
[*] The detect time does not include the delay time caused by a time constant of external Rpd and Cpd.  
6.1 TEMPALM  
TEMPALM is generated when the following relation is established after digitally comparing the A-to-D  
converted temperature sensor output value (R_TEMP [7:0]) with the ALM set value (R_TEMPALM) :  
R_TEMPE_TEMPALM  
6.2 OPTALM  
1/3, 1/4, 1/6 or 1/7 value of the APC target value (apc_ref) can be set as OPTALM set value (optalm_ref) by  
RE_OPTALM setting. OPTALM detect is done by an analog comparator and it is generated when the following  
relation is established  
vpdoptalm_ref  
6.3 CURRALM  
CURRALM is generated when one of the following 3 conditions is met after digitally comparing DAC setting  
value for Modulation current (R_DAC1 [I-DAC1 set value] or R_DAC3 [V-DAC3 set value]) or DAC setting value  
for Bias current (R_DAC2 [I-DAC2 set value]) with the CURRALM setting value (R_CURRALM_BIAS,  
R_CURRALM_MOD):  
R_DAC2 (Upper 4 bits)R_CURRALM_BIAS  
or R_DAC1(Upper 4 bits)R_CURRALM_MOD, or R_DAC3(Upper 4 bits)R_CURRALM_MOD  
Alarm threshold values R_CURRALM_BIAS and R_CURRALM_MOD can be set in accordance with the LD  
temperature characteristic (Set by approximately every 6 step with the data in E_CURRALM_BIAS_TC,  
E_CURRALM_MOD_TC, Refer to Table 9-3).  
CURRALM is also generated when either of R_DAC1 (R_DAC3) or R_DAC2 becomes its full code (FFh).  
When a shutdown request is made, CURRALM is set to “Inactive“ polarity.  
6.4 EXTALM1, EXTALM2  
When the same polarity ALM signal is input on EXTALM1-pin as set by RE_EXTALM1_POL, EXTALM1  
detection is made. On the other hand, when the same polarity ALM signal is input on EXTALM2 /  
MOD_CTRL-pin as set by RE_EXTALM2_POL, EXTALM2 detection is made if RE_PWR_LVL1_SET”0” or  
RE_SFP_SET”0” (EXTALM2 / MOD_CTRL -pin is set to EXTALM2-pin)  
When RE_EXTALM1/2_POL"0", the ALM detect polarity of “H” at EXTALM1/2-pin is set.  
When RE_EXTALM1/2_POL"1", the ALM detect polarity of “L” at EXTALM1/2-pin is set.  
-27-  
< MS0290-E-01>  
2004/8  