[AK09916]
8. Electrical Characteristics
The following conditions apply unless otherwise noted:
Vdd = 1.65V to 1.95V, Temperature range = -30˚C to +85˚C.
8.1. DC Characteristics
Parameter
High level input voltage
Low level input voltage
Input current
Hysteresis input voltage
Low level output voltage
Current consumption
Symbol
VIH
VIL
IIN
VHS
VOL
IDD1
IDD2
IDD3
Pin
SCL
SDA
SCL
SDA
SCL
SDA
SCL
SDA
SDA
VDD
IOL
≤
+3mA
Power-down mode
Vdd = 1.95V
When magnetic sensor
is driven
Self-test mode
1
1.5
2.5
Condition
Min.
70%Vdd
-0.3
VIN = Vss or Vdd
-10
10%Vdd
20%Vdd
3
3
4
Typ.
Max.
Unit
V
V
µA
V
V
µA
mA
mA
30%Vdd
+10
(Note 1)
(Note 2)
(Note 3)
Schmitt trigger input (reference value for design)
Output is Open-drain. Connect a pull-up resistor externally. Maximum capacitive load: 400pF
(Capacitive load of each bus line for I
2
C bus interface).
Without any resistance load. It does not include the current consumed by external loads
(pull-down resister, etc.). SDA = SCL = Vdd or 0V.
015007392-E-02
-5-
2015/12