[AK09916]  
10. Serial Interface  
10.1. I2C Bus Interface  
The I2C bus interface of AK09916 supports the Standard mode (100 kHz max.) and the Fast mode (400 kHz  
max.).  
10.1.1. Data Transfer  
To access AK09916 on the bus, generate a start condition first.  
Next, transmit a one-byte slave address including a device address. At this time, AK09916 compares the  
slave address with its own address. If these addresses match, AK09916 generates an acknowledgement, and  
then executes READ or WRITE instruction. At the end of instruction execution, generate a stop condition.  
10.1.1.1. Change of Data  
A change of data on the SDA line must be made during Lowperiod of the clock on the SCL line. When  
the clock signal on the SCL line is High, the state of the SDA line must be stable. (Data on the SDA line  
can be changed only when the clock signal on the SCL line is Low.)  
During the SCL line is High, the state of data on the SDA line is changed only when a start condition or a  
stop condition is generated.  
SCL  
SDA  
DATA LINE  
STABLE :  
DATA VALID  
CHANGE  
OF DATA  
ALLOWED  
Figure 10.1. Data Change  
10.1.1.2. Start/Stop Condition  
If the SDA line is driven to Lowfrom Highwhen the SCL line is High, a start condition is generated.  
Every instruction starts with a start condition.  
If the SDA line is driven to Highfrom Lowwhen the SCL line is High, a stop condition is generated.  
Every instruction stops with a stop condition.  
SCL  
SDA  
START CONDITION  
STOP CONDITION  
Figure 10.2. Start and Stop Condition  