Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Input Voltage
Symbol
T
A
V
DD1
, V
DD2
V
IN+
,V
IN-
Min.
-40
4.5
-200
Max.
85
5.5
200
Unit
°C
V
mV
Note
1
DC Electrical Specifications
All specifications, typicals and figures are at the nominal operating conditions of V
IN+
= 0 V, V
IN-
= 0 V,
T
A
= 25°C, V
DD1
= 5 V and V
DD2
= 5 V, unless otherwise noted.
Parameter
Symbol Min. Typ. Max. Unit
Test Conditions
Fig. Note
Input Offset Voltage
V
OS
-1.2 -0.2 1.0 mV
1
2
-3.0 -0.2 2.0
-40°C
≤
T
A
≤
85°C
1,2,3
4.5
≤
(V
DD1
, V
DD2
)
≤
5.5 V
Gain
G
7.60 8.00 8.40 V/V -200
≤
V
IN+
≤
200 mV
5
7.44 8.00 8.56
-200
≤
V
IN+
≤
200 mV
5,6,7
-40°C
≤
T
A
≤
85°C
4.5
≤
(V
DD1
, V
DD2
)
≤
5.5 V
200 mV Nonlinearity
NL
200
0.1
0.2
% -200
≤
V
IN+
≤
200 mV
5, 8
3
0.4
-200
≤
V
IN+
≤
200 mV
5,8,9
-40°C
≤
T
A
≤
85°C
10,12
4.5
≤
(V
DD1
, V
DD2
)
≤
5.5 V
100 mV Nonlinearity
NL
100
0.05 0.1
-100
≤
V
IN+
≤
100 mV
5, 8
0.2
-100
≤
V
IN+
≤
100 mV
5,8,9
-40°C
≤
T
A
≤
85°C
11,12
4.5
≤
(V
DD1
, V
DD2
)
≤
5.5 V
Maximum Input Voltage
|V
IN+
|
320
mV
4
MAX
Before Output Clipping
Average Input Bias Current
I
IN
-0.57
µA
13
4
Average Input Resistance
R
IN
480
kΩ
Input DC Common-Mode
CMRR
IN
69
dB
5
Rejection Ratio
Output Resistance
R
O
1
Ω
Output Low Voltage
V
OL
1.28
V V
IN+
= 400 mV
4
6
Output High Voltage
V
OH
3.84
V V
IN+
= -400 mV
Output Common-Mode
V
OCM
2.20 2.56 2.80 V -400 < V
IN+
< 400 mV
Voltage
-40°C
≤
T
A
≤
85°C
Input Supply Current
I
DD1
8.7 15.5 mA 4.5
≤
(V
DD1
, V
DD2
)
≤
5.5 V 14
Output Supply Current
I
DD2
8.8 14.5 mA
15
Output Short-Circuit Current |I
OSC
|
11
mA V
OUT
= 0 V or V
DD2
7
1-251