Regulatory Information
The HCPL-7800 has been
approved by the following
organizations:
UL
CSA
VDE
Recognized under UL 1577,
Component Recognition
Program, File E55361.
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
Approved according to VDE
0884/06.92.
Insulation and Safety Related Specifications
Parameter
Symbol Value Units
Conditions
Min. External Air Gap
(External Clearance)
Min. External Tracking
Path (External Creepage)
Min. Internal Plastic Gap
(Internal Clearance)
L(IO1)
7.4
8.0
0.5
mm
mm
mm
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity
L(IO2)
Tracking Resistance
(Comparative Tracking
Index)
CTI
175
III a
V
DIN IEC 112/VDE 0303 Part 1
Isolation Group
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
VDE 0884 (06.92) Insulation Characteristics
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
I-IV
I-III
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)*
Maximum Working Insulation Voltage
40/100/21
2
V
IORM
848
V peak
V peak
Input to Output Test Voltage, Method b**
VPR = 1.875 x VIORM, Production test with tp = 1 sec,
Partial discharge < 5 pC
VPR
1591
Input to Output Test Voltage, Method a**
VPR = 1.5 x VIORM, Type and sample test with tp = 60 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage tTR = 10 sec)
VPR
1273
6000
V peak
V peak
VTR
Safety-limiting values (Maximum values allowed in the event
of a failure, also see Figure 27)
Case Temperature
Input Power
TS
175
80
°C
mW
mW
PS,Input
Output Power
PS,Output
250
Insulation Resistance at TS, VIO = 500 V
RS
≥ 1x1012
Ω
*This part may also be used in Pollution Degree 3 environments where the rated mains voltage is ≤ 300 V rms (per DIN VDE 0110).
**Refer to the front of the optocoupler section of the current catalog for a more detailed description of VDE 0884 and other product
safety requirements.
Note: Optocouplers providing safe electrical separation per VDE 0884 do so only within the safety-limiting values to which they are
qualified. Protective cut-out switches must be used to ensure that the safety limits are not exceeded.