25. Short circuit current is the amount of  
output current generated when either  
output is shorted to VDD2 or ground.  
26. IMR (also known as CMR or Common  
Mode Rejection) specifies the mini-  
mum rate of rise of an isolation mode  
noise signal at which small output  
perturbations begin to appear. These  
output perturbations can occur with  
both the rising and falling edges of the  
isolation-mode wave form and may be  
of either polarity. When the perturba-  
tions first appear, they occur only  
occasionally and with relatively small  
peak amplitudes (typically 20-30 mV  
at the output of the recommended  
application circuit). As the magnitude  
of the isolation mode transients  
the isolation mode gain (input pins  
tied to pin 4 and the signal applied  
between the input and the output of  
the isolation amplifier) at 60 Hz,  
expressed in dB.  
29. Data sheet value is the differential  
amplitude of the transient at the  
output of the HCPL-7800 when a  
1 Vpk-pk, 1 MHz square wave with 5 ns  
rise and fall times is applied to both  
28. Output noise comes from two primary  
sources: chopper noise and sigma-  
delta quantization noise. Chopper  
noise results from chopper stabiliza-  
tion of the output op-amps. It occurs  
at a specific frequency (typically 200  
kHz at room temperature), and is not  
attenuated by the internal output filter.  
A filter circuit can be easily added to  
the external post-amplifier to reduce  
the total rms output noise. The  
VDD1 and VDD2.  
30. This is a two-terminal measurement:  
pins 1-4 are shorted together and pins  
5-8 are shorted together.  
31. In accordance with UL1577, for  
devices with minimum VISO specified at  
3750 Vrms, each optocoupler is proof-  
tested by applying an insulation test  
voltage greater-than-or-equal-to 4500  
Vrms for one second (leak current  
detection limit, II-O < 5 µA). This test  
is performed before the method b,  
100% production test for partial  
internal output filter does eliminate  
most, but not all, of the sigma-delta  
quantization noise. The magnitude of  
the output quantization noise is very  
small at lower frequencies (below 10  
kHz) and increases with increasing  
frequency. See applications section for  
more information.  
increase, the regularity and amplitude  
of the perturbations also increase. See  
applications section for more  
discharge shown in the VDE 0884  
Insulation Characteristics Table.  
32. Case temperature was measured with a  
thermocouple located in the center of  
the underside of the package.  
information.  
27. IMRR is defined as the ratio of  
differential signal gain (signal applied  
differentially between pins 2 and 3) to  
1500  
MEAN  
± 2 SIGMA  
+5 V  
+5 V  
+15 V  
1000  
500  
0.1 µF  
HCPL-7800  
0.1 µF  
0.1 µF  
10 K  
8
7
1
2
3
4
+
V
0
OUT  
6
5
AD624CD  
GAIN = 1000  
-
10 K  
-500  
0.1 µF  
0.33 µF  
0.33 µF  
-1000  
-40 -20  
0
20  
40  
60  
80  
100  
T
– TEMPERATURE – °C  
A
-15 V  
Figure 1. Input Offset Voltage Test Circuit.  
Figure 2. Input-Referred Offset Drift  
vs. Temperature.  
1-224  