4
Package Pin Out  
1
2
3
4
5
6
7
8
V
V
V
V
16  
15  
IN+  
E
V
IN-  
LED2+  
DESAT 14  
CC1  
GND1  
V
13  
12  
11  
10  
9
CC2  
RESET  
FAULT  
V
C
V
OUT  
V
V
V
LED1+  
EE  
EE  
V
LED1-  
Pin Descriptions  
Symbol  
Description  
Non-inverting gate drive voltage output  
(V ) control input.  
Symbol  
Description  
Common (IGBT emitter) output supply  
voltage.  
VIN+  
VIN-  
VE  
OUT  
Inverting gate drive voltage output  
(V ) control input.  
VLED2+ LED 2 anode. This pin must be left uncon-  
nected for guaranteed data sheet  
performance. (For optical coupling testing  
only)  
OUT  
VCC1  
Positive input supply voltage. (4.5 V to 5.5 V)  
DESAT Desaturation voltage input. When the voltage  
on DESAT exceeds an internal reference  
voltage of 7 V while the IGBT is on, FAULT  
output is changed from a high impedance  
state to a logic low state within 5 µs. See  
Note 25.  
GND1 Input Ground.  
VCC2  
VC  
Positive output supply voltage.  
RESET FAULT reset input. A logic low input for at  
least 0.1 µs, asynchronously resets FAULT  
output high and enables VIN. Synchronous  
control of RESET relative to VIN is required.  
RESET is not affected by UVLO. Asserting  
RESET while VOUT is high does not affect  
Collector of output pull-up triple-darlington  
transistor. It is connected to VCC2 directly or  
through a resistor to limit output turn-on  
current.  
VOUT  
.
FAULT Fault output. FAULT changes from a high  
impedance state to a logic low output within  
5 µs of the voltage on the DESAT pin  
exceeding an internal reference voltage of  
7 V. FAULT output remains low until RESET  
is brought low. FAULT output is an open  
collector which allows the FAULT outputs  
from all HCPL-316Js in a circuit  
V
OUT  
Gate drive voltage output.  
to be connected together in a “wired OR”  
forming a single fault bus for interfacing  
directly to the micro-controller.  
VLED1+ LED 1 anode. This pin must be left uncon-  
nected for guaranteed data sheet per-  
VEE  
Output supply voltage.  
formance. (For optical coupling testing only)  
VLED1- LED 1 cathode. This pin must be connected  
to ground.  