7
Regulatory Information
The HCPL-316J has been approved by the following
organizations:
UL
Recognized under UL 1577, component recognition
program, File E55361.
IEC/EN/DIN EN 60747-5-2
Approved under:
CSA
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
I - IV
I - III
I - II
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
55/100/21
2
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
V
IORM
891
V
PEAK
V
IORM
x 1.875 = V , 100% Production Test with t = 1 sec,
V
PR
1670
V
PEAK
PR
m
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a**
V
x 1.5 = V , Type and Sample Test, t = 60 sec,
V
1336
6000
V
PEAK
IORM
PR
m
PR
Partial Discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage t = 10 sec)
V
IOTM
V
PEAK
ini
Safety-limiting values - maximum values allowed in the event of
a failure, also see Figure 2.
Case Temperature
Input Power
T
175
400
1200
°C
mW
mW
S
P
P
S, INPUT
Output Power
S, OUTPUT
9
Insulation Resistance at T , V = 500 V
R
>10
Ω
S
IO
S
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application. Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations
section IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
1400
P , OUTPUT
S
1200
1000
P , INPUT
S
800
600
400
200
0
0
25 50 75 100 125 150 175 200
T
– CASE TEMPERATURE – °C
S
Figure 2. Dependence of Safety Limiting Values on Temperature.