Data Sheet  
June 1999  
ORCA Series 3C and 3T FPGAs  
The multiplied output is selected by setting register six,  
bits [5:4] to 10 or 11 for ExpressCLK output and/or bits  
[7:6] to 10 for system clock output. Note that when reg-  
ister six, bits [5:4] are set to 11, the ExpressCLK output  
is divided by DIV2, while the system clock cannot be  
divided. The ExpressCLK divider is provided so that the  
I/O clocking provided by the ExpressCLK can operate  
slower than the internal system clock. This allows for  
very fast internal processing while maintaining slower  
interface speeds off-chip for improved noise and power  
performance or to interoperate with slower devices in  
the system.  
Programmable Clock Manager (PCM)  
(continued)  
Clock Multiplication  
An output clock that is a multiple (not necessarily an  
integer multiple) of the input clock can be generated in  
PLL mode. The multiplication ratio is programmed in  
the division registers DIV0, DIV1, and DIV2. Note that  
DIV2 applies only to the ExpressCLK output of the  
PCM and any reference to DIV2 is implicitly 1 for the  
system clock output of the PCM. The clock multiplica-  
tion formulas when using ExpressCLK feedback are:  
It is also necessary to configure the internal PCM oscil-  
lator for operation in the proper frequency range.  
Table 29 and Table 30 show the settings required for  
register four for a given frequency range for Series 3C  
and 3T devices. In addition, the acquisition time is  
shown for each frequency range. This is the time that is  
required for the PCM to acquire LOCK. The PCM oscil-  
lator frequency range is chosen based on the desired  
output frequency at the system clock output. If using  
the ExpressCLK output, the equivalent system clock  
frequency can be selected by multiplying the expected  
ExpressCLK output frequency by the value for DIV2.  
Choose the nominal frequency from the table that is  
closest to the desired frequency, and use that value to  
program register four. Minor adjustments to match the  
exact input frequency are then performed automatically  
by the PCM.  
DIV1  
ExpressCLK_OUT  
INPUT_CLOCK  
F
= F  
DIV0  
SYSTEM_CLOCK_OUT  
ExpressCLK_OUT  
DIV2  
F
= F  
Where the values of DIV0, DIV1, and DIV2 range from  
1 to 8.  
The ExpressCLK multiplication range of output clock  
frequencies is, therefore, from 1/8x up to 8x, with the  
system clock range up to 8x the ExpressCLK frequency  
or 64x the input clock frequency. If system clock feed-  
back is used, the formulas are:  
DIV1  
SYSTEM_CLOCK_OUT  
INPUT_CLOCK  
F
= F  
DIV0  
SYSTEM_CLOCK  
/DIV2  
ExpressCLK_OUT  
F
= F  
The divider values, DIV0, DIV1, and DIV2 are pro-  
grammed in registers zero, one, and two, respectively.  
Lucent Technologies Inc.  
77  