DC ELECTRICAL CHARACTERISTICS 1
( -55°C < TC < +125°C) (T C = -55°C to +125°C for "C" screening and -40°C to +125°C for "W" screening)
SYMBOL
PARAMETER
CONDITION
MIN
MAX
UNIT
Schmitt Trigger, positive going threshold2
Schmitt Trigger, negative going threshold2
Schmitt Trigger range of hysteresis10
VT+
VDD from 3.00 to 5.5
.7VDD
V
VT-
VDD from 3.00 to 5.5
.3VDD
0.6
V
V
VH1
VDD from 4.5 to 5.5
VDD from 3.00 to 3.6
Schmitt Trigger range of hysteresis10
Input leakage current10
VH2
IIN
0.4
-1
V
VDD from 3.6 to 5.5
VIN = VDD or VSS
3
3
mA
Three-state output leakage current10
Cold sparing leakage current3
Short-circuit output current 6, 11
Short-circuit output current 6, 11
Low-level output voltage4, 10
IOZ
VDD from 3.6 to 5.5
VIN = VDD or VSS
-1
mA
mA
mA
mA
V
ICS
VIN = 5.5
-1
5
VDD = VSS
IOS1
IOS2
VOL1
VO = VDD or VSS
-200
-100
200
100
VDD from 4.5 to 5.5
VO = VDD or VSS
VDD from 3.00 to 3.6
IOL= 8mA
0.4
0.2
IOL= 100mA
VDD = 4.5
Low-level output voltage4, 10
High-level output voltage4, 10
High-level output voltage4, 10
IOL= 8mA
VOL2
VOH1
VOH2
0.5
0.2
V
V
V
IOL= 100mA
VDD = 3.00
IOH= -8mA
VDD - 0.7
VDD - 0.2
IOH= -100mA
VDD = 4.5
VDD - 0.9
VDD - 0.2
IOH= -8mA
IOH= -100mA
VDD = 3.00
5