ADV7123
5 V DYNAMIC SPECIFICATIONS
VAA = 5 V 5ꢀ,1 VREF = 1.235 V, RSET = 560 Ω, CL = 10 pF. All specifications are TA = 25°C, unless otherwise noted, TJ MAX = 110°C.
Table 3.
Parameter1
Min
Typ
Max
Unit
AC LINEARITY
Spurious-Free Dynamic Range to Nyquist2
Single-Ended Output
fCLK = ꢀ0 MHz; fOUT = 1.00 MHz
fCLK = ꢀ0 MHz; fOUT = 2.ꢀ1 MHz
fCLK = ꢀ0 MHz; fOUT = ꢀ.04 MHz
fCLK = ꢀ0 MHz; fOUT = 20.2 MHz
fCLK = 100 MHz; fOUT = 2.ꢀ1 MHz
fCLK = 100 MHz; fOUT = ꢀ.04 MHz
fCLK = 100 MHz; fOUT = 20.2 MHz
fCLK = 100 MHz; fOUT = 40.4 MHz
fCLK = 140 MHz; fOUT = 2.ꢀ1 MHz
fCLK = 140 MHz; fOUT = ꢀ.04 MHz
fCLK = 140 MHz; fOUT = 20.2 MHz
fCLK = 140 MHz; fOUT = 40.4 MHz
Double-Ended Output
67
67
63
ꢀꢀ
62
60
ꢀ4
48
ꢀ7
ꢀ8
ꢀ2
41
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
fCLK = ꢀ0 MHz; fOUT = 1.00 MHz
fCLK = ꢀ0 MHz; fOUT = 2.ꢀ1 MHz
fCLK = ꢀ0 MHz; fOUT = ꢀ.04 MHz
fCLK = ꢀ0 MHz; fOUT = 20.2 MHz
fCLK = 100 MHz; fOUT = 2.ꢀ1 MHz
fCLK = 100 MHz; fOUT = ꢀ.04 MHz
fCLK = 100 MHz; fOUT = 20.2 MHz
fCLK = 100 MHz; fOUT = 40.4 MHz
fCLK = 140 MHz; fOUT = 2.ꢀ1 MHz
fCLK = 140 MHz; fOUT = ꢀ.04 MHz
fCLK = 140 MHz; fOUT = 20.2 MHz
fCLK = 140 MHz; fOUT = 40.4 MHz
Spurious-Free Dynamic Range Within a Window
Single-Ended Output
70
70
6ꢀ
ꢀ4
67
63
ꢀ8
ꢀ2
62
61
ꢀꢀ
ꢀ3
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
fCLK = ꢀ0 MHz; fOUT = 1.00 MHz; 1 MHz Span
fCLK = ꢀ0 MHz; fOUT = ꢀ.04 MHz; 2 MHz Span
fCLK = 140 MHz; fOUT = ꢀ.04 MHz; 4 MHz Span
Double-Ended Output
77
73
64
dBc
dBc
dBc
fCLK = ꢀ0 MHz; fOUT = 1.00 MHz; 1 MHz Span
fCLK = ꢀ0 MHz; fOUT = ꢀ.00 MHz; 2 MHz Span
fCLK = 140 MHz; fOUT = ꢀ.00 MHz; 4 MHz Span
Total Harmonic Distortion
74
73
60
dBc
dBc
dBc
fCLK = ꢀ0 MHz; fOUT = 1.00 MHz
TA = 2ꢀ°C
TMIN to TMAX
fCLK = ꢀ0 MHz; fOUT = 2.00 MHz
fCLK = 100 MHz; fOUT = 2.00 MHz
fCLK = 140 MHz; fOUT = 2.00 MHz
66
6ꢀ
64
63
ꢀꢀ
dBc
dBc
dBc
dBc
dBc
Rev. D | Page ꢀ of 24