ADuM1410/ADuM1411/ADuM1412
DIN EN 60747-5-2 (VDE 0884 PART 2) INSULATION CHARACTERISTICS
These isolators are suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN EN 60747-5-2 approval.
Table 7.
Description
Conditions
Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
I to IV1
I to III
I to II
40/105/21
2
VIORM
VPR
560
1050
V peak
V peak
VIORM × 1.875 = VPR, 100% Production Test, tm = 1 sec,
partial discharge < 5 pC
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2 VIORM × 1.2 = VPR, tm = 60 sec, Partial Discharge < 5 pC
and Subgroup 3
VIORM × 1.6 = VPR, tm = 60 sec, Partial Discharge < 5 pC
VPR
896
672
V peak
V peak
Highest Allowable Overvoltage
Safety-Limiting Values
Transient overvoltage, tTR = 10 seconds
Maximum value allowed in the event of a failure; see
Figure 7
VTR
4000
V peak
Case Temperature
Side 1 Current
Side 2 Current
TS
IS1
IS2
RS
150
265
335
>109
°C
mA
mA
Ω
Insulation Resistance at TS
VIO = 500 V
1 See DIN VDE 0110 for definition of Classification 1 through Classification IV listed in the Characteristic column.
Rev. E | Page 11 of 20