欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADUM1410BRWZ 参数 Datasheet PDF下载

ADUM1410BRWZ图片预览
型号: ADUM1410BRWZ
PDF下载: 下载PDF文件 查看货源
内容描述: 四通道数字隔离器 [Quad-Channel Digital Isolators]
分类和应用: 驱动程序和接口接口集成电路光电二极管
文件页数/大小: 20 页 / 517 K
品牌: ADI [ ADI ]
 浏览型号ADUM1410BRWZ的Datasheet PDF文件第6页浏览型号ADUM1410BRWZ的Datasheet PDF文件第7页浏览型号ADUM1410BRWZ的Datasheet PDF文件第8页浏览型号ADUM1410BRWZ的Datasheet PDF文件第9页浏览型号ADUM1410BRWZ的Datasheet PDF文件第11页浏览型号ADUM1410BRWZ的Datasheet PDF文件第12页浏览型号ADUM1410BRWZ的Datasheet PDF文件第13页浏览型号ADUM1410BRWZ的Datasheet PDF文件第14页  
ADuM1410/ADuM1411/ADuM1412  
PACKAGE CHARACTERISTICS  
Table 4.  
Parameter  
Symbol  
RI-O  
CI-O  
CI  
θJCI  
Min  
Typ  
1012  
2.2  
4.0  
33  
Max  
Unit  
Ω
pF  
pF  
°C/W  
°C/W  
Test Conditions  
Resistance (Input-to-Output)1  
Capacitance (Input-to-Output)1  
Input Capacitance2  
f = 1 MHz  
IC Junction-to-Case Thermal Resistance, Side 1  
IC Junction-to-Case Thermal Resistance, Side 2  
Thermocouple located at  
center of package underside  
θJCO  
28  
1 The ADuM141x device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.  
2 Input capacitance is from any input data pin to ground.  
REGULATORY INFORMATION  
The ADuM141x have been approved by the organizations listed in Table 5.  
Table 5.  
UL1  
CSA  
VDE2 (ADuM1411 and ADuM1412 pending)  
Recognized under 1577  
component recognition  
program1  
Approved under CSA Component  
Acceptance Notice #5A  
Certified according to DIN EN 60747-5-2  
(VDE 0884 Part 2): 2003-012  
1 In accordance with UL1577, each ADuM141x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 second (current leakage detection limit = 5 μA).  
2 In accordance with DIN EN 60747-5-2, each ADuM141x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection  
limit = 5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.  
INSULATION AND SAFETY-RELATED SPECIFICATIONS  
Table 6.  
Parameter  
Symbol Value  
Unit Conditions  
Rated Dielectric Insulation Voltage  
Minimum External Air Gap (Clearance)  
2500  
7.7 min  
V rms 1 minute duration  
L(I01)  
L(I02)  
mm  
Measured from input terminals to output terminals,  
shortest distance through air  
Minimum External Tracking (Creepage)  
8.1 min  
mm  
Measured from input terminals to output terminals,  
shortest distance path along body  
Minimum Internal Gap (Internal Clearance)  
Tracking Resistance (Comparative Tracking Index)  
Isolation Group  
0.017 min mm  
Insulation distance through insulation  
DIN IEC 112/VDE 0303 Part 1  
Material Group (DIN VDE 0110, 1/89, Table 1)  
CTI  
>175  
IIIa  
V
Rev. E | Page 10 of 20