欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADUM1301ARW 参数 Datasheet PDF下载

ADUM1301ARW图片预览
型号: ADUM1301ARW
PDF下载: 下载PDF文件 查看货源
内容描述: 三通道数字隔离器 [Triple-Channel Digital Isolators]
分类和应用:
文件页数/大小: 20 页 / 1122 K
品牌: AD [ ANALOG DEVICES ]
 浏览型号ADUM1301ARW的Datasheet PDF文件第6页浏览型号ADUM1301ARW的Datasheet PDF文件第7页浏览型号ADUM1301ARW的Datasheet PDF文件第8页浏览型号ADUM1301ARW的Datasheet PDF文件第9页浏览型号ADUM1301ARW的Datasheet PDF文件第11页浏览型号ADUM1301ARW的Datasheet PDF文件第12页浏览型号ADUM1301ARW的Datasheet PDF文件第13页浏览型号ADUM1301ARW的Datasheet PDF文件第14页  
ADuM1300/ADuM1301
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)
Capacitance (Input-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol
R
I-O
C
I-O
C
I
θ
JCI
θ
JCO
Min
Typ
10
12
1.7
4.0
33
28
Max
Unit
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located
at center of package
underside
1
2
Device considered a 2-terminal device; Pins 1, 2, 3, 4, 5, 6, 7, and 8 shorted together and Pins 9, 10, 11, 12, 13, 14, 15, and 16 shorted together.
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM130x have been approved by the organizations listed in Table 5.
Table 5.
UL
Recognized under 1577
component recognition program
Double insulation, 2500 V rms
isolation voltage
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
400 V rms maximum working voltage
VDE
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2):2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950:2000
Reinforced insulation, 560 V peak
File 2471900-4880-0001
File E214100
File 205078
1
2
In accordance with UL1577, each ADuM130x is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA).
In accordance with DIN EN 60747-5-2, each ADuM130x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC). A “*” mark branded on the component designates DIN EN 60747-5-2 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Symbol
L(I01)
L(I02)
Value
2500
8.40 min
8.10 min
Unit
V rms
mm
mm
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
0.017 min mm
>175
V
IIIa
Rev. C | Page 10 of 20