欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADUM1201ARZ 参数 Datasheet PDF下载

ADUM1201ARZ图片预览
型号: ADUM1201ARZ
PDF下载: 下载PDF文件 查看货源
内容描述: 双通道数字隔离器 [Dual-Channel Digital Isolators]
分类和应用: 驱动程序和接口接口集成电路光电二极管PC
文件页数/大小: 20 页 / 1156 K
品牌: AD [ ANALOG DEVICES ]
 浏览型号ADUM1201ARZ的Datasheet PDF文件第6页浏览型号ADUM1201ARZ的Datasheet PDF文件第7页浏览型号ADUM1201ARZ的Datasheet PDF文件第8页浏览型号ADUM1201ARZ的Datasheet PDF文件第9页浏览型号ADUM1201ARZ的Datasheet PDF文件第11页浏览型号ADUM1201ARZ的Datasheet PDF文件第12页浏览型号ADUM1201ARZ的Datasheet PDF文件第13页浏览型号ADUM1201ARZ的Datasheet PDF文件第14页  
ADuM1200/ADuM1201
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)
Capacitance (Input-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol
R
I-O
C
I-O
C
I
θ
JCI
θ
JCO
Min
Typ
10
12
1.0
4.0
46
41
Max
Unit
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at center of
package underside
1
The device is considered a 2-terminal device; Pins 1, 2, 3, and 4 are shorted together, and Pins 5, 6, 7, and 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200/ADuM1201 have been approved by the following organizations:
Table 5.
UL
Recognized under 1577 Component
Recognition Program
2500 V rms isolation voltage
CSA
Approved under CSA Component
Acceptance Notice #5A
VDE
Certified according to
DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884
Part 2): 2003-01, DIN EN 60950 (VDE 0805): 2001-12;
EN 60950: 2000, Reinforced insulation, 560 V peak
File E214100
File 205078
File 2471900-4880-0001
1
2
In accordance with UL1577, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA).
In accordance with DIN EN 60747-5-2, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal
Clearance)
Tracking Resistance (Comparative
Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
Value
2500
4.90 min
4.01 min
0.017 min
CTI
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals, shortest
distance through air
Measured from input terminals to output terminals, shortest
distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. B | Page 10 of 20