 浏览型号ADE7761AARS-REF的Datasheet PDF文件第3页浏览型号ADE7761AARS-REF的Datasheet PDF文件第4页浏览型号ADE7761AARS-REF的Datasheet PDF文件第5页浏览型号ADE7761AARS-REF的Datasheet PDF文件第6页浏览型号ADE7761AARS-REF的Datasheet PDF文件第8页浏览型号ADE7761AARS-REF的Datasheet PDF文件第9页浏览型号ADE7761AARS-REF的Datasheet PDF文件第10页浏览型号ADE7761AARS-REF的Datasheet PDF文件第11页  
ADE7761A  
Pin No. Mnemonic Description  
15  
FAULT  
This logic output goes active high when a fault or missing neutral condition occurs. A fault is defined as a  
condition under which the signals on V1A and V1B differ by more than 6.25%. A missing neutral condition is  
defined when the chip is powered up with no voltage at the input. The logic output is reset to zero when a fault  
or missing neutral condition is no longer detected. See the Fault Detection section and the Missing Neutral Mode  
section.  
16  
17  
REVP  
This logic output goes logic high when negative power is detected, that is, when the phase angle between the  
voltage and current signals is greater than 90°. This output is not latched and is reset when positive power is once  
again detected. The output goes high or low at the same time as a pulse is issued on CF.  
This pin provides the ground reference for the digital circuitry in the ADE7761A, that is, multiplier, filters, and  
digital-to-frequency converters. This pin should be tied to the digital ground plane of the PCB. The digital ground  
plane is the ground reference for all digital circuitry, such as counters (mechanical and digital), MCUs, and  
indicator LEDs. For good noise suppression, the analog ground plane should be connected only to the digital  
ground plane at the DGND pin.  
DGND  
18  
CF  
Calibration Frequency Logic Output. The CF logic output, active high, gives instantaneous active power  
information. This output is used for operational and calibration purposes. See the Digital-to-Frequency Conversion  
section.  
19, 20  
F2, F1  
Low Frequency Logic Outputs. F1 and F2 supply average active power information. The logic outputs can be  
used to directly drive electromechanical counters and 2-phase stepper motors.  
Rev. 0 | Page 7 of 24  