AD590
Model
AD 590L
Typ
AD 590M
Typ
Min
Max
Min
Max
Units
ABSOLUT E MAXIMUM RAT INGS
Forward Voltage ( E+ or E–)
Reverse Voltage (E+ to E–)
Breakdown Voltage (Case to E+ or E–)
Rated Performance T emperature Range1
Storage T emperature Range1
+44
–20
±200
+150
+155
+300
+44
–20
±200
+150
+155
+300
Volts
Volts
Volts
°C
°C
°C
–55
–65
–55
–65
Lead T emperature (Soldering, 10 sec)
POWER SUPPLY
Operating Voltage Range
+4
+30
+4
+30
Volts
OUT PUT
Nominal Current Output @ +25°C (298.2K)
Nominal T emperature Coefficient
Calibration Error @ +25°C
Absolute Error (Over Rated Performance T emperature Range)
Without External Calibration Adjustment
With ±25°C Calibration Error Set to Zero
Nonlinearity
298.2
1
298.2
1
µA
µA/K
°C
؎1.0
؎0.5
؎3.0
؎1.6
؎0.4
±0.1
±0.1
؎1.7
؎1.0
؎0.3
±0.1
±0.1
°C
°C
°C
°C
Repeatability2
Long-T erm Drift3
°C
Current Noise
40
40
pA/√Hz
Power Supply Rejection
+4 V ≤ VS ≤ +5 V
+5 V ≤ VS ≤ +15 V
+15 V ≤ VS ≤ +30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical T urn-On T ime
Reverse Bias Leakage Current4
(Reverse Voltage = 10 V)
0.5
0.2
0.1
1010
100
20
0.5
0.2
0.1
1010
100
20
µA/V
µA/V
µA/V
Ω
pF
µs
10
10
pA
PACKAGE OPT IONS
T O-52 (H-03A)
Flatpack (F-2A)
AD590LH
AD590LF
AD590MH
AD590MF
TEMP ERATURE SCALE CO NVERSIO N EQUATIO NS
5
°C = (°F – 32) K = °C +273.15
9
9
°F = °C + 32
°R = °F +459.7
5
–3–
REV. B