(@ +25؇C and V = +5 V unless otherwise noted)
AD590–SPECIFICATIONS
S
Model
AD 590J
AD 590K
Typ
Min
Typ
Max
Min
Max
Units
ABSOLUT E MAXIMUM RAT INGS
Forward Voltage ( E+ or E–)
Reverse Voltage (E+ to E–)
Breakdown Voltage (Case E+ or E–)
Rated Performance T emperature Range1
Storage T emperature Range1
+44
–20
±200
+150
+155
+300
+44
–20
±200
+150
+155
+300
Volts
Volts
Volts
°C
°C
°C
–55
–65
–55
–65
Lead T emperature (Soldering, 10 sec)
POWER SUPPLY
Operating Voltage Range
+4
+30
+4
+30
Volts
OUT PUT
Nominal Current Output @ +25°C (298.2K)
Nominal T emperature Coefficient
Calibration Error @ +25°C
Absolute Error (Over Rated Performance T emperature Range)
Without External Calibration Adjustment
With +25°C Calibration Error Set to Zero
Nonlinearity
298.2
1
298.2
1
µA
µA/K
°C
؎5.0
؎2.5
؎10
؎5.5
؎2.0
؎0.8
±0.1
±0.1
°C
°C
°C
°C
؎3.0
؎1.5
±0.1
±0.1
Repeatability2
Long-T erm Drift3
°C
Current Noise
40
40
pA/√Hz
Power Supply Rejection
+4 V ≤ VS ≤ +5 V
+5 V ≤ VS ≤ +15 V
+15 V ≤ VS ≤ +30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical T urn-On T ime
Reverse Bias Leakage Current4
(Reverse Voltage = 10 V)
0.5
0.2
0.1
1010
100
20
0.5
0.2
0.1
1010
100
20
µA/V
µV/V
µA/V
Ω
pF
µs
10
10
pA
PACKAGE OPT IONS
T O-52 (H-03A)
Flatpack (F-2A)
AD590JH
AD590JF
AD590KH
AD590KF
NOT ES
1T he AD590 has been used at –100°C and +200°C for short periods of measurement with no physical damage to the device. However, the absolute errors
specified apply to only the rated performance temperature range.
2Maximum deviation between +25°C readings after temperature cycling between –55°C and +150°C; guaranteed not tested.
3Conditions: constant +5 V, constant +125°C; guaranteed, not tested.
4Leakage current doubles every 10°C.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels.
All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
REV. B