4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified herein. Quality conformance inspection for
device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed
for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a. Tests shall be as specified in table IIA herein.
b. Subgroups 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
TABLE IIA. Electrical test requirements.
Subgroups
Subgroups
(in accordance with
(in accordance with
MIL-PRF-38535, table III)
Test requirements
MIL-STD-883,
method 5005, table I)
Device
Device
class Q
Device
class V
class M
Interim electrical
1, 2, 3
1, 2, 3, 4 1/
1, 2, 3, 4, 5, 6
1, 2, 3
1, 2, 3
1, 2, 3, 4 1/
1, 2, 3, 4, 5, 6
1, 2, 3
1
parameters (see 4.2)
Final electrical
1, 2, 3, 4, 5, 6
1/, 2/
parameters (see 4.2)
Group A test
1, 2, 3, 4, 5, 6
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
1 2/
1, 2, 3
1, 2, 3
1
1
- - -
- - -
1/ PDA applies to subgroup 1. Deltas excluded from PDA.
2/ Delta limits as specified in table IIB shall be required where specified, and delta limits shall
be computed with reference to the previous endpoint electrical parameters.
Table IIB. 240 hour burn-in and group C end-point electrical parameters.
End-Point
Delta
Max
Unit
V
Parameter
Device type
01, 03
Min
Max
9.97
10.03
±0.006
V
OUT
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a. Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b. TA = +125°C, minimum.
c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
SIZE
STANDARD
5962-89479
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
E
SHEET
COLUMBUS, OHIO 43218-3990
9
DSCC FORM 2234
APR 97