TABLE I. Electrical performance characteristics.
Conditions
-55°C ≤ TA ≤+125°C 1/
unless otherwise specified
Test
Symbol
RA
Group A
subgroups
Device
type
Limits
Max
Unit
Min
ALL
Relative accuracy 2/
VX = -10 V, -10 V, +10 V, +10 V
VY = -10 V, +10 V, -10 V, +10 V
4
±0.5
%FS
1, 2, 3
±1
±0.01
±0.3
±0.1
±30
±45
±15
±300
±20
±10
±20
±10
±2
ALL
ALL
ALL
ALL
Multiplier accuracy Drift
Nonlinearity, X Input
Nonlinearity, Y Input
Output offset voltage
TCMA
NLX
NLY
VOS
2, 3
4
%/°C
VX = 20 V pk-pk, VY = +10 V
VY = 20 V pk-pk, VX = +10 V
VX = VY = VZ = 0 V
%
%
4
1
mV
2, 3
4
ALL
ALL
Output offset voltage drift
Offset voltage (X)
2, 3
1
∆VOS/∆T
µV/°C
VOSX
VX = VZ = 0 V, VY = ±10 V
VY = VZ = 0 V, VX = ±10 V
VX = VY = VZ = 0 V
mV
4
ALL
ALL
mV
Offset voltage (Y)
VOSY
1
4
Input bias current
(X, Y, or Z)
IIB
1
µA
ALL
ALL
ALL
ALL
µA
mA
mA
dB
Input offset current
IOS
ICC
VX = VY = VZ = 0 V
RL = No Load
1
1
1
4
±2
6.0
6.0
Positive supply current
Negative supply current
RL = No Load
IEE
Common mode rejection
ratio
CMRX
70
-10 V ≤ VX ≤ +10 V, VY = +10 V
CMRY
VOP
4
1, 2, 3
9
70
±11
50
-10 V ≤ VY ≤ +10 V, VX = +10 V
ALL
ALL
Output voltage swing
1% amplitude error
V
AE
VX = 2 V pk-pk, CL = 1000 pF,
VY = +10 V
kHz
ALL
ALL
Feedthrough, X input 3/
Feedthrough, Y input 3/
FRR
FRR
Y Nulled, X = 20 V pk-pk at
50Hz
9
9
±0.30
±0.10
%FS
%FS
X Nulled, Y = 20 V pk-pk at
50Hz
1/ VS = ±15V unless otherwise specified.
2/ Figures given are % of Full Scale, ±10V (i. e., 0.01% = 1mV).
3/ Irreducible component due to nonlinearity: excludes effects of offsets.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-90537
A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
D
SHEET
5
DSCC FORM 2234