 浏览型号5962-8876403XX的Datasheet PDF文件第5页浏览型号5962-8876403XX的Datasheet PDF文件第6页浏览型号5962-8876403XX的Datasheet PDF文件第7页浏览型号5962-8876403XX的Datasheet PDF文件第8页浏览型号5962-8876403XX的Datasheet PDF文件第10页浏览型号5962-8876403XX的Datasheet PDF文件第11页浏览型号5962-8876403XX的Datasheet PDF文件第12页浏览型号5962-8876403XX的Datasheet PDF文件第13页  
AD7824/AD7828  
MODE 0  
MODE 1  
Figure 14 shows the timing diagram for Mode 0 operation. This  
mode can only be used for microprocessors that have a WAIT  
state facility, whereby a READ instruction cycle can be extended  
to accommodate slow memory devices. A READ operation brings  
CS and RD low, which starts a conversion. The analog multiplexer  
address inputs must remain valid while CS and RD are low. The  
data bus (DB7–DB0) remains in the three-state condition until  
conversion is complete. There are two converter status outputs on  
the AD7824/AD7828, interrupt (INT) and ready (RDY), which  
can be used to drive the microprocessor READY/WAIT input.  
The RDY is an open-drain output (no internal pull-up device) that  
goes low on the falling edge of CS and goes high impedance at the  
end of conversion when the 8-bit conversion result appears on the  
data outputs. If the RDY status is not required, the external  
pull-up resistor can be omitted and the RDY output tied to GND.  
The INT goes low when conversion is complete and returns high  
on the rising edge of CS or RD.  
Mode 1 operation is designed for applications where the micropro-  
cessor is not forced into a WAIT state. A READ operation takes  
CS and RD low, which triggers a conversion (see Figure 15). The  
multiplexer address inputs are latched on the rising edge of RD.  
Data from the previous conversion is read from the three-state  
data outputs (DB7–DB0). This data may be disregarded if not  
required. Note that the RDY output (open drain output) does  
not provide any status information in this mode and must be  
connected to GND. At the end of conversion, INT goes low. A  
second READ operation is required to access the new conversion  
result. This READ operation latches a new address into the multi-  
plexer inputs and starts another conversion. INT returns high at the  
end of the second READ operation, when CS or RD returns high.  
A delay of 2.5 µs must be allowed between READ operations.  
CS  
tCSH  
tCSS  
tCSS  
RD  
tP  
tAS  
tAS  
ANALOG  
CHANNEL  
ADDRESS  
ADDRESS  
VALID  
ADDRESS  
VALID  
tAH  
RDY  
tRDY  
tINTH  
INT  
tCRD  
tACC2  
tDH  
HIGH IMPEDANCE  
DATA  
VALID  
DATA  
Figure 14. Mode 0 Timing Diagram  
CS  
RD  
tCSS  
tCSH  
tCSS  
tCSH  
tRD  
tRD  
tP  
tAS  
tAS  
ANALOG  
CHANNEL  
ADDRESS  
ADDRESS  
VALID  
ADDRESS  
VALID  
tAH  
tCRD  
tAH  
tINTH  
tINTH  
INT  
tACC1  
tDH  
tACC1  
tDH  
OLD  
VALID  
NEW  
VALID  
DATA  
Figure 15. Mode 1 Timing Diagram  
REV. F  
–9–