ACT8892
Rev 2, 01-Jul-15
SYSTEM CONTROL ELECTRICAL CHARACTERISTICS
(VVP1 = VVP2 = VVP3 = 3.6V, TA = 25°C, unless otherwise specified.)
PARAMETER
Input Voltage Range
TEST CONDITIONS
MIN
2.7
TYP
MAX
5.5
UNIT
V
UVLO Threshold Voltage
UVLO Hysteresis
VVDDREF Rising
2.2
2.45
200
2.65
V
VVDDREF Falling
mV
REG1 Enabled. REG2, REG3, REG4,
150
285
420
REG5, REG6 and REG7 Disabled
REG1, REG2, REG3 Enabled. REG4
REG5, REG6 and REG7 Disabled
Supply Current
µA
REG1, REG2, REG3, REG4, REG5,
REG6 and REG7 Enabled
Shutdown Supply Current
Oscillator Frequency
All Regulators Disabled
1.5
2
3.0
2.2
µA
MHz
V
1.8
1.4
Logic High Input Voltage
Logic Low Input Voltage
Leakage Current
0.4
1
V
VnIRQ = VnRSTO = 4.2V
ISINK = 5mA
µA
V
Low Level Output Voltage
0.35
nRSTO Delay
65
160
20
ms
°C
°C
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
Temperature rising
: PWRHLD, nHIB, VSEL are logic inputs.
: nPBSTAT, nIRQ, nRSTO are open drain outputs.
: Typical value shown. Actual value may vary from 56.3ms to 72.8ms.
Innovative PowerTM
- 14 -
www.active-semi.com
Copyright © 2015-2017 Active-Semi, Inc.
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.