ACT5830
SYSTEM MANAGEMENT
ELECTRICAL CHARACTERISTICS
(V
BAT
= V
IN1
= V
IN2
= 3.6V, T
A
= 25°C, unless otherwise specified.)
Rev PrB, 05-Mar-08
PARAMETER
BAT Operating Voltage Range
BAT UVLO Threshold
BAT UVLO Hysteresis
BAT UVLO Delay
nRST Delay
No Load BAT Supply Current
REF Output Voltage
Reference PSRR
ODx Output On Resistance
ODx Output Leakage Current
Logic High Input Voltage
Logic Low Input Voltage
Logic Low Output Voltage
Logic Leakage Current
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
TEST CONDITIONS
BAT Voltage Rising
BAT Voltage Falling
BAT Rising
BAT Falling
MIN
2.6
2.2
TYP
2.35
80
0.1
5
65
MAX UNIT
5.5
2.5
V
V
mV
ms
ms
0.5
0.75
1.26
mA
mA
V
dB
Ω
10
µA
V
0.4
V
V
µA
°C
°C
REG, LDO1, LDO2 and LDO3 Enabled with
No Load and CHGR Disabled
REG, All LDOs Enabled and CHGR Disabled.
1.24
C
REF
= 0.01µF
100mA Sink Current
V
ODx
= V
BAT
1.4
0.26
0.45
1.25
75
4
nON, nRST, I
SINK
= 5mA
V
nON
= V
nRST
= V
CHG_IN
= 4.2V
Temperature rising
Temperature falling
160
20
0.3
1
Innovative Power
TM
ActivePMU
is a trademark of Active-Semi.
I
2
C
TM
is a trademark of Philips Electronics.
TM
-8-
www.active-semi.com
Copyright © 2008 Active-Semi, Inc.